| ALLEN-BRADLEY · 2097-V31PR2 | PRODUCTSYSTEM FITSUPPLYFAQMODELS |
|
KINETIX 300 INDEXING SERVO DRIVE
Compact Indexing With EtherNet/IP Control2097-V31PR2
The 2097-V31PR2 is a Kinetix 300 EtherNet/IP indexing servo drive for single-phase 120/240 V AC input. It provides 4 A continuous output current and a 0.8 kW continuous power class without an integral AC line filter. |
120/240 V
Single-phase AC input 4.0 A
Continuous output 0.8 kW
Continuous power |
| Product identity | Kinetix 300 EtherNet/IP indexing servo drive |
| Input supply | 120/240 V AC, single phase |
| Continuous output current | 4.0 A rms |
| Peak output current | 12.0 A rms |
| Continuous power output | 0.8 kW |
| Line filter | No integral AC line filter |
| Control interface | EtherNet/IP indexing control |
| Safety function | Hardwired Safe Torque Off architecture |
| Motor relationship | Use only with compatible motor, feedback and power cabling |
| Replacement control | Match voltage code, current class, filter arrangement and application settings |
| Send the motor catalog number and existing drive settings for replacement review. | ASK MIYA TO CHECK |
| 2097-V31PR0 | 2 A, 0.4 kW, 120/240 V | Lower current class |
| 2097-V31PR2 | 4 A, 0.8 kW, 120/240 V | Selected drive |
| 2097-V32PR2 | 4 A, 0.8 kW, 240 V | Integral-filter variant |
| Higher-current variants | Greater motor current and power | Different branch protection |
Physical similarity alone does not establish interchangeability. Confirm the complete catalog number, installed system and electrical or mechanical configuration together.
| EMAIL · SALES@AMIKON.CN | WHATSAPP · 86-18020776792 | SALES MANAGER · MIYA ZHENG |
| Contact us within seven days if a concern appears after receipt. | Keep the item in its original condition and state the reason. Resolution follows receipt and inspection. | Return-related shipping charges are paid by the buyer. |
| 01 |
2097-V31PR2 — Is 2097-V31PR2 the same as 2097-V32PR2?
No. Both are 4 A classes, but their input and integral-filter arrangements differ. Confirm the complete catalog number and cabinet design.
|
| 02 |
2097-V31PR2 — What must be retained before replacing 2097-V31PR2?
Record the drive settings, indexing profile, electronic gearing, I/O assignments, network address, motor catalog number and machine-specific tuning.
|
| 03 |
2097-V31PR2 — Can 2097-V31PR2 be connected to any servo motor?
No. Motor power, feedback type, current demand, voltage class and cable combination must be compatible with the drive.
|
| 04 |
2097-V31PR2 — Why does the missing integral filter matter for 2097-V31PR2?
The cabinet EMC design may require external filtering, correct grounding and shield termination. A filtered variant changes the installation arrangement.
|
| 05 |
2097-V31PR2 — What should be tested after commissioning 2097-V31PR2?
Check motor direction, feedback, travel limits, overtravel inputs, registration, indexing accuracy, stopping behavior and Safe Torque Off before production.
|
| DVS-005I00 | VXZ2A3AZ3AX66A | V420AM2525CL060 | 6GK5108-0BA00-2AC2 |
| 836-00430 | 140ACO13000 | FU-95Z | ADV569-P00 |
| RL4RD022TD 113026 | 6ES7510-1SK03-0AB0 | GHIC-50.8-85 | 75HC0125 |
| 289041 H19A | SA1U-T50MTR | BGS-V80CN | E3S-AD32 |
| SS-6-BT | GHGR 31.7-3 | EK1100 | XEC-DN32H |
| IC200CPUE05 | NX-ID6142-5 | 505-4332 TI505 | GT1155-QSBD |
| EVD0000UC0 | A-751-116-9B | LA-166 | E3T-ST13R |
| ML703 KQ07071 | 074-02-005 | ER16 7165.16110 | KL2101X1-BB1 |
| 1469470000 | 33-0941D | PK602HK001 | A393.CG-20 |
| TM2AMM6HT | 6ES7647-0AA00-1YA2 | 146031-01 | 08-A 10278203 |
| 2020GM00RX | P528-650-S-C2C | 851020-120VAC | 11-312E-06-HP |
| 204-450-000-002 | 17L65104S-LW4 | A-1051-0417 | NS-BHP7003-0 |
| D4NL-4CFA-B | 2198-H040-AT | IC200CPUE05-EG | TCM4355X |
| A12-FC-XX-C1 | 050-3 RH 1188853 | EVM50L0316MC | 2525M 08-A 10278203 |



Inventory Products


More than 40.000.000 products available and worldwide support