The RH916JT is a Foxboro Evo termination assembly used with the FBM211 input module when loop power for field devices comes from a customer-supplied external DC source. It provides compression-terminal field wiring and connects to the associated FBM through the specified Type 4 termination cable. RH916JT supersedes the earlier P0916JT designation.
EXACT-MATCH QUOTATION
Send the full part number, quantity, condition requirement and destination.
Use RH916JT only where the installed channel uses FBM211 with externally supplied loop power. Confirm the termination cable, compression-terminal wiring, hazardous-location requirements, loop source, polarity, grounding and channel allocation before replacement.
SERIES / SYSTEM RELATIONSHIP
Choose by Installed Role, Not Appearance
IDENTITY
RELATIONSHIP
SELECTION POINT
RH916JT
FBM211; external loop-power source
◆ THIS MODEL
RH916BT
FBM211; FBM auxiliary +24 V DC
Different loop-power arrangement
P0916JT
Earlier designation
Superseded by RH916JT
P0916PQ
PVC alternative shown for the same duty
Different construction and temperature range
◆
Separates field loop power from the FBM auxiliary supply arrangement.
◇
Compression terminals support orderly field-wire landing and service checks.
◈
Defined FBM211 pairing reduces ambiguity during system maintenance.
◉
Type 1 and 2 certification classes support specified industrial installations.
20 Years of Industrial Automation Supply
GLOBAL RESPONSE
Fast coordination for planned maintenance and urgent recovery.
QUALITY CHECK
Part-number, condition and outward checks support reliable delivery.
STOCK & DELIVERY
Experienced sourcing for current and discontinued automation parts.
Contact us within seven days if a concern appears after receipt.
Keep returned items in original condition and state the reason for review.
Return-related shipping costs are the buyer’s responsibility.
PURCHASING FAQ
Checks That Protect the Installation
RH916JT: Can RH916JT replace RH916BT without wiring changes?
No. RH916JT uses customer-supplied external loop power, while RH916BT uses the FBM auxiliary +24 V DC arrangement. Review the complete loop design.
RH916JT: Is RH916JT the current replacement for P0916JT?
Yes, RH916JT supersedes P0916JT for the stated FBM211 external-loop-power termination role; verify installed cabling and certification requirements.
RH916JT: Which cable is required with RH916JT?
The termination relationship calls for Type 4 cable. Confirm the exact cable part, length, connector condition and routing before installation.
RH916JT: What should be checked before energizing RH916JT?
Verify external DC supply rating, polarity, channel wiring, shields, grounds, terminal tightness, FBM211 seating and absence of unintended field voltage.
RH916JT: How should RH916JT channels be commissioned?
Test each loop from field device to FBM211, verify scaling and diagnostics, then confirm open-circuit behavior, grounding and process response channel by channel.