Honeywell DCS System

HONEYWELL

Home Brands HONEYWELL

Honeywell CC-ZHR041 Series C Network/Communication Module

Honeywell CC-ZHR041 Series C Network/Communication Module

 
HONEYWELL · PROCESS AUTOMATION
CC-ZHR041
 
C200 → C300
Redundant Upgrade Kit
 
 
 
REDUNDANCY
Dual-controller architecture
for modernization of existing
C200 process control systems.
ARCHITECTURE
2 × C300
redundant controllers
FIREWALL
8 + 1
ports + uplink
KIT TYPE
UHIO
C200 / CB / EC / HPM
01

C300 / CF9
Two horizontal C300 / CF9 IOTA assemblies

 

02

Control Firewall
Two 8-port + 1 uplink modules

 

DIRECT CONTACT
Miya zheng
Sales Manager
 
Connecting automation expertise with dependable parts.
 
EXPERION PKS • CONTROL PLATFORM
CC-ZHR041
 
KIT TYPE
C300 Upgrade Kit
ARCHITECTURE
Controller + Firewall
Designed around the C300 migration architecture, with two controller and nine-port control-firewall sets incorporated into the upgrade configuration.
 
 
 
 
CORE CONFIGURATION
2 × C300
Controller sets
9-port
Control Firewall
Migration-oriented architecture
01 C300 Migration 02 Dual Controller Sets 03 9-Port Firewall 04 Experion PKS
01 / CONFIGURATION

Core Architecture

 
 
The CC-ZHR041 upgrade configuration contains **two sets of C300 Controller and 9-port Control Firewall**.
The architecture is intended for modernization work where an existing C300 / PMIO environment is being migrated toward a newer control platform.
CC-ZHR041 STRUCTURE
CONTROLLER SETS
02
C300 Controller sets
FIREWALL PORTS
09
Ports per Control Firewall
PLATFORM
Experion PKS
CONTROL ELEMENT
C300
02 / FIELD CONTEXT

When the Existing
Control Layer Becomes Critical

 

CC-ZHR041 is associated with C300 modernization and migration work within the Experion PKS environment. It becomes especially relevant when an installed C300 / PMIO architecture must be transitioned while maintaining a controlled path toward a newer platform.

A
Migration Trigger
A C300 / PMIO control environment is approaching a modernization stage and the migration architecture becomes a purchasing consideration.
B
Replacement Search
Searches commonly arise when an existing control component or migration path cannot be kept operational and a matching upgrade configuration is required.
C
Downtime Exposure
Because controller architecture is part of the process-control layer, an unavailable replacement can extend troubleshooting, migration preparation, or planned shutdown windows.
03 / RELATED HONEYWELL ARCHITECTURE

Migration-Oriented Selection

CC-ZHR041
C300 → New Platform
Two C300 Controller and 9-port Control Firewall sets.
 
CC-ZHR042
PMIO Migration
Associated with a C200 PMIO migration path toward PCNT05.
 
CC-ZHER01
Series A Migration
A newer migration route associated with C200 Series A I/O toward PCNT05.
04 / FAQ

CC-ZHR041 Purchase Questions

01. What makes CC-ZHR041 different from a single C300 controller replacement?
CC-ZHR041 is an upgrade-kit configuration containing two sets of C300 Controller and 9-port Control Firewall. It therefore addresses a broader migration architecture rather than a single controller position.
 
02. When should an engineer consider this part number?
It is relevant when planning a C300 / PMIO migration where the control architecture must move toward a newer Honeywell platform and the required upgrade configuration includes the dual controller/firewall arrangement.
03. Could another C300-related upgrade kit be the better choice?
Yes. Honeywell migration paths differ according to the existing architecture. CC-ZHR041 is associated with C200 PMIO migration toward a C300v5 environment, while other upgrade kits address different migration routes. The existing controller, I/O architecture and target platform should therefore be checked before ordering.
 
04. What should be checked before requesting a quotation?
For a faster quotation, provide the exact part number, quantity, destination, required date and the machine/system in which the existing control architecture is installed.
05. Why can availability of this type of kit matter during a plant migration?
Controller migration work is normally tied to planned engineering and shutdown windows. If the required upgrade configuration is unavailable when the migration window arrives, commissioning schedules and downtime planning can be affected.
 
06. Is CC-ZHR041 simply an interchangeable single-module spare?
No. Its configuration is a kit containing two C300 Controller and 9-port Control Firewall sets, so selection should be based on the complete migration architecture rather than on a single module footprint.
05 / RELATED PART NUMBERS

Additional Automation Models

NL-3313 EB501-10 706580 / 08-220-33/020 PSM 3010
IC200CPUE05-GK N5454NC-98 171CCC78010 172PNN21022
170AMM09000 iQ7 DA6 MKB-2
COM0008 2RCA013892A0001H 10310/2/1 NFAI835-H00
1009201000 60255100 SCD2200-RTU DO-2 I/O P0924AW
X67DM1321.L12 FC-PDB-0824P 644HFI5J2Q4 COMPACT-24
180LR 180LG 51438-03 SGDE-02VS
Sentinel-A-774 FP3070TN SDV144-S53 CP6020 -0000-0000
06 / SERVICE PHILOSOPHY
More capability.
More connection.
We aim to make industrial automation sourcing more connected, responsive and practical for customers working with difficult-to-source control components.
Multilingual Support
Communication support for customers across different markets.
Order Tracking
A structured approach to customer relations and order progress.
Global Reach
Automation components supplied to customers across international markets.
Transparent Process
No additional handling or hidden charges are added to the quotation.
Team
TEAM
Warehouse
WAREHOUSE
Customer
CUSTOMER CONNECTION
07 / ORDER DETAILS

Quotation Checklist

PART NUMBER
CC-ZHR041
QUANTITY
Required quantity
DESTINATION
Delivery destination
REQUIRED DATE
Target delivery date
MACHINE / SYSTEM
Existing machine or control system
COMMERCIAL TERMS
Delivery 3–5 days
Warranty 12 months
Condition Brand New
Payment T/T
Delivery Way E-packing / FedEx / EMS / TNT / DHL / UPS

 

08 / CONTACT
Need CC-ZHR041?
Send the part number, quantity, destination, required date and machine/system details for a quotation.
SALES MANAGER
Miya zheng
EMAIL
sales@amikon.cn
PHONE / WHATSAPP
86-18020776792
09 / AFTER-SALES

Return & Replacement

01
Please contact us within 7 days after receiving the item if any issue requires attention.
02
Returned items should remain in their original condition and include the specific reason for return. A return or replacement can be arranged after the returned item is received.
03
Shipping expenses associated with the return are the responsibility of the buyer.
HONEYWELL CC-ZHR041 Industrial Automation Components
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Honeywell CC-PDOB01 51405043-175 Digital Output 24V Module
Honeywell CC-PDOB01 51405043-175 Digital Output 24V Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-TAIH02 51304453-150 Analog Input Board
Honeywell MC-TAIH02 51304453-150 Analog Input Board

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-TAMR03 51309218-175 Low Level Analog I/O Module
Honeywell MC-TAMR03 51309218-175 Low Level Analog I/O Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-TAOY22 51204172-175 Analog Output Module
Honeywell MC-TAOY22 51204172-175 Analog Output Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-TDID12 51304441-175 Digital Input 24VDC Module
Honeywell MC-TDID12 51304441-175 Digital Input 24VDC Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-PAIH03 51304754-150 High Level Analog Input Module
Honeywell MC-PAIH03 51304754-150 High Level Analog Input Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell MC-TAMT04 51305890-175 Thermocouple input terminal board
Honeywell MC-TAMT04 51305890-175 Thermocouple input terminal board

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Honeywell 8C-PDOD51 51454361-175 Digital Output 24V Module
Honeywell 8C-PDOD51 51454361-175 Digital Output 24V Module

● Honeywell DCS TDC2000 TDC3000 TPS PKS FSC   ● C200 series: TC TK   ● C300 series: CC 8C   ● UCN series: MC + number   ● FTA Board series: MC   ● FSC matching terminal series: FC   WeChat: hu18030235311   Mobile/WhatsApp: +86-18030235311   RFQ E-mail: sales3@amikon.cn  

Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact