GE
GENIUS
ISOLATED
I/O |
GE GENIUS I/O
IC660BBS100
115 VAC / 125 VDC · 8-Circuit Isolated I/O
Isolated Genius I/O for field circuits where electrical separation matters.
|
ISOLATED
CONTROL |
| GE | IC660BBS100 | Overview Technical Profile Application FAQ Contact |
|
GENIUS ISOLATED I/O
IC660BBS100
115 VAC / 125 VDC · 8-Circuit Isolated I/O
Four isolated groups provide separation between field circuits, making this family suitable for mixed industrial loads where electrical isolation is important.
|
FAST QUOTE
Replacing BBS100?
Send your exact part number together with quantity, destination, required date and machine/system. Miya zheng
|
| Model | IC660BBS100 | Block type | 115 VAC / 125 VDC isolated I/O |
| Circuit count | 8 configurable I/O circuits | Isolation structure | 4 isolated groups × 2 circuits |
| Operating voltage | AC 93–132 V / DC 105–132 V | Block-to-block isolation | 1500 V |
| Isolation withstand | 250 VAC/VDC continuous | Transient rating | 2000 V peak / 10 sec |
| Input filtering | Selectable 10–100 ms | Failed Switch | Diagnostic capability |
| Genius Remote I/O
The block belongs to the Genius distributed I/O architecture and can handle configurable field input/output circuits. |
Why It Is Searched
It becomes a practical replacement target when an existing isolated circuit stops responding correctly or when field isolation performance must be restored. |
Production Risk
Loss of one I/O block can affect several field points at once, potentially interrupting a machine sequence or process interlock. |
| Why is isolation the key matching point for BBS100? | Because the eight circuits are arranged in four electrically isolated pairs. Replacing it with a non-isolated eight-point block can change the field-side architecture. |
| Does BBS100 support both inputs and outputs? | Yes. The block is configurable for I/O operation, with the specific circuit role determined by configuration and field wiring. |
| What does Failed Switch Diagnostic help detect? | For an output, the diagnostic compares the commanded state with the actual state of the block's internal switch, helping identify a switching discrepancy. |
| What operating voltage should be checked before purchase? | The specified operating range is 93–132 VAC or 105–132 VDC. The existing field circuit and control-power arrangement should be checked before replacement. |
| Is BBS102 interchangeable with BBS100? | They belong to the same eight-circuit isolated family, but BBS102 is the later low-leakage variant and should be matched against the actual application requirements rather than assumed identical. |
|
AMIKON GLOBAL SERVICE
Parts Support Without BordersFrom hard-to-find automation components to international delivery coordination, our team works to make replacement sourcing simpler and faster. |
|||
|
|
Recommended Models
|
||
| NFCP100-S0E | 176F2137 | ABE7-CPA31 |
| SGDM-15DN | ABE7-CPA31 | EHD3020VL |
| DVI021 DKL015 | FLATPACK2 241119.903 | 95-200-41 |
| FTDR-M2-WSA | EF8316G034 | D37902030 |
| PS-6 1100-0072 | 6V2100 | 162VTS-151-045-00 |
| 5860005000 | FD4015L | ICR-3200 ICR-3231 |
| 362 98146953-V02 | 3500/42M 176449-02V | FDC8T |
| 35548-001B | GCA44FS | TWL-1S |
| 5310G | TPMC871-10 | SGDM-05DN |