| GE | IC660BBR101 | Overview Technical Profile Application FAQ Contact |
|
GENIUS DISCRETE I/O
IC660BBR101
115/230 VAC Normally Open Relay Output Block
A practical replacement choice when an existing Genius relay-output point must be restored without changing the original control architecture.
|
QUICK QUOTE
Need IC660BBR101?
Send the part number, quantity, destination, required date and machine/system.
|
| Model | IC660BBR101 | Output type | Normally Open relay |
| Output points | 16 relay output circuits | Grouping | 4 independent groups of 4 |
| Block supply | 115 / 230 VAC | Group output range | 5–250 VAC or 5–220 VDC |
| Typical architecture | Genius remote discrete I/O with relay switching for field loads | ||
| Control Architecture
Designed for Genius distributed discrete control environments where relay outputs interface the controller with field devices. |
Typical Replacement Trigger
Engineers commonly look for this exact part when an output group no longer switches a contactor, actuator or other field load as commanded. |
Downtime Exposure
A failed relay point can prevent a machine sequence from starting, stop an interlocked process or leave a controlled load unavailable. |
| Will a BBR101 replacement preserve the normally-open behavior? | Yes. The defining output arrangement is 16 normally-open relay outputs, so the replacement should be matched to the same NO configuration rather than only by the 16-point count. |
| Why does the four-group arrangement matter? | The 16 outputs are arranged as four groups of four, allowing the field-side power arrangement to be handled by group rather than treating all 16 points as one common circuit. |
| Can this block switch DC loads? | The relay contacts can be used with DC loads within the stated group voltage range. The field load, current and protection arrangement still need to match the actual installation. |
| What should I verify before ordering? | Confirm the exact IC660BBR101 number, normally-open configuration, group wiring, field voltage and the existing Genius architecture. |
| When is the exact part number more important than a similar relay block? | When the existing PLC logic, wiring and commissioning depend on the original Genius block behavior. A normally-closed BBR100, for example, is not an equivalent substitution for a normally-open BBR101. |
|