| GE / GENIUS I/O | Overview Specifications Application FAQ Contact |
|
GENIUS CURRENT-LOOP INPUT
IC660BBA106
115 VAC / 125 VDC six-channel current-loop input block with isolated analog channels.
|
|
|
TECHNICAL PROFILE
Six isolated current-loop inputs
IC660BBA106 provides six analog current inputs for devices delivering 4–20 mA signals. Conversion time can be selected from 16.6 ms to 400 ms, allowing the installation to balance response speed, resolution and noise rejection. |
|
|
FIELD APPLICATION
Designed for current-loop acquisition
The IC660BBA106 is suited to Genius field networks where transmitters and other 4–20 mA devices must be monitored through multiple analog channels. It may be searched for when a channel reports an abnormal value, an open-wire condition, an alarm-limit violation or when an aging input block begins affecting process supervision. |
|
| 01 — What is the key difference between IC660BBA106 and IC660BBA105?
BBA106 is a six-channel analog input block, whereas BBA105 provides six analog outputs. They serve opposite signal directions and cannot be substituted solely by matching the channel count. |
02 — Is IC660BBA026 the corresponding low-voltage version?
Yes. BBA026 is the 24/48 VDC counterpart, while BBA106 uses 115 VAC / 125 VDC block power. |
| 03 — Why does conversion time matter to an engineer?
The selectable 16.6–400 ms range allows the application to balance acquisition speed with signal quality and resolution requirements. |
04 — What should be checked if all six measurements become abnormal?
Check block power, Genius communication, common wiring conditions and loop excitation before treating all six field devices as independent failures. |
| 05 — Why is loop impedance relevant when replacing the block?
The input excitation supports specified loop-impedance limits. The field transmitter and wiring should remain within the applicable range. |
06 — What purchasing details help avoid the wrong replacement?
Provide the exact part number, quantity, destination, required date and machine/system. For engineering review, the installed power type and current-loop arrangement are also useful. |
![]() |
![]() |
![]() |
Multilingual assistance, organized customer communication and streamlined order tracking for automation-part purchasing.
|
REQUEST A QUOTE
IC660BBA106
Part Number | Quantity | Destination | Required Date | Machine/System
|
SALES CONTACT
Miya zheng
|
| TTSIM-2-230 | 723-901 | 30731808-003 | IG-642POE | CRV-05-MB |
| NS-AHA7002-0 | AIP501-S1 | 140CRP93100C | LQSE-4T10-D | R-Myra-300-P |
| 8270-274k | V1400R16 | P7620C0025B | 3.3563.024/61 | CC-PD0B01 |
| 176F3501 | GALA1005PPB200UA0010000 | HUB800 T555800E1p | SPW481-53 | Pcd3.m2330a4t5 |
| PW482-50 | CSC100 | 8R0470 | ANT512-53 | SCD2200-RTU DI-10 |
| 1756-IB{16If} | NFDV561-P00 | 55/H20.K,200-S12 | CM82-EZ-II-BK | 0745A TB600343 |



Inventory Products


More than 40.000.000 products available and worldwide support