| A1 | PR642x SENSOR | 0.35 m ADAPTER | AMS EZ 1000 |
A dedicated passive adapter that joins supported PR642x eddy-current sensors to the AMS EZ 1000 converter while adding a defined electrical contribution to the sensor circuit.
| MATCH THE FULL ORDER CODE | ✉ EMAIL MIYA | ◉ WHATSAPP +86 180 2077 6792 | Miya Zheng Sales Manager |
|
01
PRODUCT CORE
|
A controlled interface, not a converterThe adapter supports specified PR6424, PR6425 and PR6426 variants. It provides the required connector transition but does not perform signal conditioning. Its 0.35 m unarmored cable adds 39 pF and negligible inductance. These values matter when checking the total circuit limits for hazardous-area installations. |
|
|
□
VERIFY
Confirm the complete PR642x order code and converter execution. |
↔
CONNECT
Seat the mating parts without twisting or loading the sensor cable. |
→
ISOLATE
Use the specified shrink-sleeve arrangement where the installation requires it. |
| 01 PR642x sensing element |
| 02 EZ1900-003-ADAP-1 connector transition |
| 03 AMS EZ 1000 signal conversion |
|
01 / PEOPLE
Responsive multilingual support for urgent automation requirements. |
02 / CHECK
Order-code matching and accountable handling. |
03 / DELIVER
Global fulfillment focused on reducing production delay. |
| MATCH THE FULL ORDER CODE | ✉ EMAIL MIYA | ◉ WHATSAPP +86 180 2077 6792 | Miya Zheng Sales Manager |
| ORDER CARE |
Contact us within seven days after receipt if an order concern appears. Returned items must remain in original condition and include a clear reason. Return or replacement processing begins after receipt and inspection. Return-related shipping costs are the buyer's responsibility. |
| 01 |
Does EZ1900-003-ADAP-1 replace the AMS EZ 1000 converter?
No. It is a passive connection adapter; the converter performs the signal conditioning.
|
| 02 |
Which sensors can use EZ1900-003-ADAP-1?
Supported variants include PR6424/0xx-xx0, PR6425/010-1x0 and PR6426/0x0-xx0.
|
| 03 |
What does EZ1900-003-ADAP-1 add electrically?
It adds 39 pF capacitance and negligible inductance.
|
| 04 |
Is EZ1900-003-ADAP-1 armored?
No. This execution is a 0.35 m adapter without armor.
|
| 05 |
What must be checked for hazardous-area use of EZ1900-003-ADAP-1?
Check total capacitance and inductance, barrier values, converter execution, enclosure design and joint isolation.
|
| 6ES7515-2FM02-0AB0 | A200MICBM | JUSP-0P02A |
| 140DD084300 | PM858K02 3BSE082896R1 | PR9268-201-100 |
| PR6423-002-030 | 40CT-ADB | 25-7288 A 104672 |
| 2171756-01 | 140CRP93100C | C4D0112N-A |
| 1A49183H01 | RPTA-8010 | EC7850A1072 |
| 3.527-12UN-3A | HD2-FBPS-1.500 | SCB110-S2 |
| 01B010020 | KJ3222X1-EA1 | 11/16-32 UN-2B |
| IS200ESELH1A | TWDLCAA24DRF | JKH8210G073 |
| 6ES7315-2AH14-0AB0 | 6SN1118-1NJ01-0AA2 | 120-0BH01-0AA0 |
| GA-223 | AW4000-04 | CC-PFB802 51454953-176 |
| P043-1211101 | IC695ALG626-CA | 9004AE01 |
| 140EHC20200 | 2198-P070 | FRN32EINX |
| PR120-35.5 | KFD2-2TC4-EX1 | PR6423/011-040 |
| PLX51-PBS | DG101121 | PLX31-EIP-MBS |
| AT-JUNO-451 | SW-1601 | ITV2050-042N |
| SFGD301455 | Z377376059A | 1756-L65 |
| PR9268-301-100 | 1769-L35E | M37WP814857 |
| PM863K01 3BSE088381R1 | AD402T-N03X-2Z-A | 6ES7193-6AR00-0AA0 |
| 3HAC024386-001 | 2097-V32PR0 | A90L-0001-0385 |
| 140CPS11100 | 922AB2K-C6P | T8110B |
| MATCH THE FULL ORDER CODE | ✉ EMAIL MIYA | ◉ WHATSAPP +86 180 2077 6792 | Miya Zheng Sales Manager |



Inventory Products


More than 40.000.000 products available and worldwide support