SIRIUS 3RW40 • HIGH-CURRENT SOFT STARTING
3RW4076-6BB44
S12 Soft Starter for Standard Applications
High-current SIRIUS motor starting control
The Siemens 3RW4076-6BB44 is a SIRIUS 3RW40 soft starter in starter size S12. Its rated operational current is 432 A at 40°C, with a motor power rating of 250 kW at 400 V in the standard switching arrangement. The unit is designed for three-phase motor starting duties where controlled acceleration and reduced starting stress are required.
|
| Power stage | Thyristor-based semiconductor power electronics with an integrated bridging contact system for standard soft-starting applications. |
| Motor protection | Motor overload protection is integrated. The adjustable motor rated-current setting has a minimum value of 207 A. |
| Current control | Adjustable current limitation is provided for controlled starting behavior. The unit supports a continuous operating current of 115% of Ie at 40°C. |
| Thermal capability | Rated operating current is 432 A at 40°C, 385 A at 50°C and 335 A at 60°C. The operating temperature range is −25°C to +60°C. |
|
|
|
INSTALLATION
Panel-ready scale
|
|
|||||||||
|
FAMILY
3RW40
Soft starters for standard applications, using semiconductor thyristor technology and integrated bridging contact architecture.
|
Replacement planning
Siemens identifies the SIRIUS 3RW5 generation as the successor family for phased-out 3RW40 units. For the 3RW4076-6BB44, Siemens lists 3RW5076-6AB14 as the preferred successor type. A successor should be treated as a migration choice rather than an automatic one-to-one substitution; motor rating, control supply, wiring, protection and panel arrangement should be checked together.
|
| MATCHING LOGIC | When evaluating a replacement, compare the complete part number, starter size, motor power, rated current, main voltage, control supply, connection arrangement and physical dimensions rather than relying on the family name alone. |
|
AMIKON LIMITED
Tell us the exact part you need
Send the complete part number, quantity, destination and required date. For replacement projects, adding the machine or system context helps us check the appropriate configuration.
|
| DELIVERY | 3–5 Days | WARRANTY | 12 Months |
| PACKAGING | Brand New | PAYMENT | T/T |
| SHIPPING | E-packing / FedEx / EMS / TNT / DHL / UPS | ||
| 01 | Please contact us within 7 days if you have any question after you receiving the items. |
| 02 | The returned items has to be in its original condition, with a specific reason for the return. We will issue a return or replacement for your order after we received the returns. |
| 03 | The buyer is responsible for all the shipping cost incurred. |
| 01 |
Can Siemens 3RW4076-6BB44 be selected solely by matching the 250 kW motor rating?
No. The 250 kW rating applies to the specified 400 V standard switching arrangement at 40°C. A proper selection also needs the motor operating voltage, motor current, starting duty, ambient temperature, control supply, protective arrangement and panel conditions to be checked together.
|
| 02 |
What should be checked when replacing an installed Siemens 3RW4076-6BB44 with another unit?
Check the complete order code, S12 frame, 432 A rating at 40°C, 230 V AC control supply, main voltage range, terminal arrangement, enclosure space, clearances and connected motor circuit. The physical size of the replacement should also be compared with the existing panel arrangement.
|
| 03 |
Why does the 432 A rating of Siemens 3RW4076-6BB44 matter when the panel operates above 40°C?
The rated current changes with ambient temperature. The unit is rated at 432 A at 40°C, 385 A at 50°C and 335 A at 60°C. Therefore, a panel operating at a higher ambient temperature should not be evaluated using the 432 A value alone.
|
| 04 |
Is Siemens 3RW4076-6BB44 a direct one-for-one replacement for the newer 3RW5 generation?
Siemens identifies the 3RW5 family as the successor generation and lists 3RW5076-6AB14 as the preferred successor type. Because the product generation changes, the receiving circuit, control arrangement, motor application, physical installation and protection design should be checked before a migration is approved.
|
| 05 |
What makes Siemens 3RW4076-6BB44 worth checking by complete part number when sourcing an older spare?
This exact execution combines S12 size, 432 A rated current at 40°C, 200–460 V AC operating voltage, 230 V AC control supply and a specific connection arrangement. For an older installation, matching the complete 3RW4076-6BB44 designation helps avoid selecting a visually similar 3RW40 unit with a different electrical rating.
|
| CE3008 | HQ40D | SX5457M RJ45 | PR9268/617-100-CNS | A6500-TP |
| LICO690 | A5F00109409-008 | PR9268/203-100 | CE3006 | PHC10101 |
| 6SL3200-0SP06-0AA0 | NBG-12LX | MRI-M500S | T7412B1008 | UE43-3MF2D3 |
| 6RY1803-0CM20 | PHC10103 | AB7533-F | K5061WHI | C98043-A7107-L4 |
| X20BC0063 | 6SL3120-2TE21-8AD0 | CE5137 | A0352 | 6RY1803-0DB02 |
| AB7900-F | HQ30D | 800033-340SE | NT100-DN-DP/+ML | 5PP320.0571-39 |
| 5AP920.1906-K07 | 3RU2116-1AB0 | 3625A | MMK-6L | AB7699-F |
| MTN631619 | 6ES7323-1BL00-0AA0 | LICO620 | KGK-402M | DSQC-328 |
| EM-07K | T9110 | 3UG4614-1BR20 | RF3332 | DRB200 |
| F01U033343 | A3C40173228 | PR9268/200-000 | DR300 | 24347 |
| AB7800-F | EM-07E | PL-FD113S | XP10BKB/DC | F312 |
| PR9268/207-100 | DR1900 | AB7834-F | SV-200P2 | DIN-AP2 |



Inventory Products


More than 40.000.000 products available and worldwide support