PROFIBUS / CONTROLLOGIX
|
IN-CHASSIS NETWORK INTERFACE
SST-PB3-CLXPROFIBUS Communication Module for ControlLogix
The SST-PB3-CLX family places a PROFIBUS DP interface directly in a Rockwell Automation ControlLogix chassis. It exchanges cyclic process data with PROFIBUS field devices while keeping controller-side data available through the Logix environment. EMAIL SALES@AMIKON.CNWHATSAPPSales manager: Miya zheng · 86-18020776792
|
NETWORK PROFILE
12 Mbit/s
maximum PROFIBUS data rate
DP Master / DP Slave
single-channel architecture
|
| Chassis Format ControlLogix in-chassis module |
Network Port 9-pin D-sub PROFIBUS connector |
Protocol Capability DPV0 master/slave and DPV1 master |
|
01
Deterministic field exchangeDesigned to bridge Logix control data with PROFIBUS remote I/O, drives and instrumentation through a dedicated fieldbus channel. |
|
|
SYSTEM INTEGRATION
ControlLogix-to-PROFIBUS Data Path
|
Selection checkpointsExact suffix: Confirm whether the installed unit is RLL, DTM, DTS or a conformal-coated variant. Chassis fit: Reserve a compatible ControlLogix slot and verify available backplane power. Project retention: Preserve the PROFIBUS configuration and Logix mapping before replacing an operational module. Connector state: Confirm termination, shielding and the 9-pin field connector condition during commissioning. |
|
FUNCTIONAL VALUE
Why keep the installed platform?A correctly matched replacement preserves the existing fieldbus topology, controller data mapping and commissioned device set. |
Direct chassis integration No separate gateway enclosure in the standard arrangement. |
Flexible network role Supports master and slave deployment patterns. |
Service continuity Suited to maintenance of established PROFIBUS assets. |
| 1. Which SST-PB3-CLX suffix must be matched? | Match the full engineering number and license variant. RLL, DTM, DTS and conformal-coated versions can differ in supplied software entitlement and environmental construction. |
| 2. Can the existing PROFIBUS project be reused? | Usually only when the replacement variant, module configuration and controller mapping agree. Back up the SST configuration and Logix project before removal. |
| 3. What should be checked before powering the replacement? | Confirm slot assignment, backplane capacity, network address, baud rate, bus termination, cable shielding and the condition of the D-sub connector. |
| 4. How should network-role compatibility be verified? | Confirm whether the installed system uses DP master, DP slave or DPV1 services and ensure the replacement firmware and configuration support that exact role. |
| 5. What should buyers send for accurate matching? | Send clear front and side label photos, complete suffix, hardware revision, current firmware, ControlLogix platform details and any installed software license designation. |
| PV211 | IC693CPU363-DKRS | XFT100r2 42T90031 | NFAI143-H01 | 6SL3040-1NB00-0AA0 |
| G12-1300 | MB-FB-4R | ST320A-100-ASSY | SPW482-13 | QLXD4-H51 |
| IPBridge-2 | FN23 | IC697CMM742-LL | Vigil2 Bvrd2M | SM26-4 |
| AMP-330-EUR | DET4TCR/DET4TCR | ZE544002A800 | V5421B1058 | Z3-LB-R |
| SLXD4 G59 | 1MSC980037 | 456D012058 | 8270-274k | TT120 |
| 200200-03-03-05 | NT21-ST121-E | PN:50135165 | YA032HR 7940021586 | 6211/23 |
| MP4M-FC-1.00 | 1787A | 467NHP81100 | 5A26458G14 | FSH-Z2 |
| V1400R16 | 16in/16out | 03031-1045-0022 | NANO-8522E-1GZ-R13 | IC693CPU363-DKRS |
| H16x10A-R11 | SKDDI0764 | CK103 | -Myra-300-P 3P/4W | DMC-2153 |
| X13760335-01 | G12-1300 | ST320A-100-ASSY | H16x10A-R11 | SKDDI0764 |
Sales manager: Miya zheng · Include label photos, suffix, firmware and installed ControlLogix details.
EMAIL SALES@AMIKON.CNWHATSAPP 86-18020776792


Inventory Products


More than 40.000.000 products available and worldwide support