| HONEYWELL / CONTROL SYSTEMS | OverviewSpecificationsIntegrationRelated ModelsFAQ |
A four-channel System 57 control card for continuous 4-20 mA gas detector and transmitter signals. It combines channel processing, local gas-level display, alarm evaluation and rack-level communication in a compact control module.
| OPERATING PROFILE | |
|---|---|
| Product identity | 05704-A-0135 |
| Product category | Four-channel gas control card |
| System family | Honeywell Analytics System 57 / 5704 |
| Channel capacity | Up to 4 detector channels |
| Detector interface | Continuous 4-20 mA gas detector or transmitter loops |
| Display | Backlit multi-part LCD |
| Display modes | Analog bar graph, digital value and channel status |
| Alarm processing | Three configurable alarm levels |
| Alarm options | Individual, zoned, voted, master, delayed, update and rate-of-rise logic |
| Local controls | Alarm reset and engineering-card selection |
| Channel data | Gas reading, channel number and operating status |
| Sensor functions | Peak reading and sensor performance monitoring |
| Configuration storage | Non-volatile EEPROM |
| Rack formats | Full 19-inch or half 19-inch System 57 rack |
| System support | Engineering Card for configuration and calibration |
| Typical use | Fixed gas detection in process and utility areas |
| FIELD DETECTORS Four independent 4-20 mA detector loops provide continuous gas measurements. |
CONTROL CARD Microprocessor processing converts loop current into gas values and status. |
ALARM LOGIC Configurable thresholds, delay, voting and rate-of-rise functions drive responses. |
SYSTEM 57 RACK Engineering and interface cards support configuration, relay action and wider indication. |
| Q1 | Which detector signal is required? Confirm that each field detector or transmitter provides the 4-20 mA signal expected by the configured channel. |
| Q2 | What should be supplied for compatibility checking? Provide the full part number, rack type, installed interface assembly, detector type and existing card revision. |
| Q3 | Can catalytic detectors be connected directly? Use the control-card variant intended for catalytic bridge detectors; do not assume the 4-20 mA variant is interchangeable. |
| Q4 | How are alarm settings maintained? Channel setup is retained in non-volatile memory and is managed through the System 57 engineering functions. |
| Q5 | What should be checked after replacement? Verify channel scaling, zero, span, alarm thresholds, relay actions and detector-loop fault monitoring before returning the system to service. |
| RAIO-01 64379224F | 51305391-300 | CS-SS-RHR1HE-03 |
| 05V-0070L | 2711P-K6C20A | 79835-66515 |
| FTA-T-20 | REF615E_D REF615E-D | ALR121-S51 S1 |
| AAT145-S50 S1 | C98043-A7600-L1 | VPM-8100LS-000 |
| SNT521-53 | NA50-40NAMKNN-CE | VPM-8100Q-000 |
| 194r-c30-1753 | 51196742-200 | MA40-7073 |
| FC-IO-0001 V1.1 | FS-USI-0001 | EPDM 76/DN80/3 |
| NFDV551-P11 | 140DAO85300 | ASS9981DE-02 |
| SAI143-H63 S4 | 1747-KFC15 | 81003-438-51-R |
| D200175 AP31 | MSD013A1Y | RDIO-01 64379216D |
| 51308097-200 | A413141 BIU82 | DSQC323 3HAB5956-1 |
| 22TA-L4-SS | 11-018-164 | 2080-DNET20 |
| MSD5AZA1Y | 4L-E4-C1A-TT | DSQC256A 3HAB2211-1 |
| 103147 SAE-14 | 02-681-339 | 07KR91 GJR5250000R0151 |
| FIO-11 68679079 | SDV144-S33 S2 | FC-CPCHAS-0001 |
| FC-TSAO-0220M | 1785-L60B/C | WMZT3D20T |
| 51305896-100 | 4L-L4-M2-B1A | 1KHW001356R0001 P4RX |
| 71503-052130 | 1797-IE8NF | FC-BKM-0001 V1.1 |
| SPW481-13 | DSQC239 YB560103-CH | TM80125 |
| E24KN9ZCCM | 51196990-500 | K9634DA K9634DA-01 |
Send the complete part number, quantity, destination and target delivery date for a focused quotation.
CONTACT SALES


Inventory Products


More than 40.000.000 products available and worldwide support