  MODEL: HIMA X-CB 001
01 / FUNCTION TYPE  
Connection Board
System cable interface & signal terminal module
 
02 / SYSTEM FIT
HIMax Safety System
Dedicated module & rack bus integration
 
03 / SAFETY RATING
SIL 3 Certified
TÜV IEC 61508 fault-tolerant safety
  We operate globally and are open to all customer requirements.
SALES MANAGER
Miya zheng
Email: sales@amikon.cn
Phone/WhatsApp: 86-18020776792
HIMAX / CONNECTOR BOARD OVERVIEW ARCHITECTURE APPLICATION FAQ CONTACT
HIMAX • CONNECTOR INTERFACE
X-CB 001
 
HIMax Connector Board

The X-CB 001 01 connector board is designed for the HIMax processor environment. It forms a functional unit with the X-CPU 01 and provides the external Ethernet connections used for communication with other HIMA controllers and the PADT.

TYPE
X-CB 001 01
 
INTERFACE
Ethernet
 
PORTS
Eth1–Eth4
CONNECTOR BOARD
X-CB 001
 
ETH 1 X3
ETH 2 X4
ETH 3 X5
ETH 4 X6
HIMax / Ethernet connection layer
   
01 / SYSTEM POSITION
A connection layer
inside HIMax
 

X-CB 001 01 connects the HIMax processor module with external Ethernet connections. Together with the processor module, the connector board forms a functional unit.

Connection role
Communication with other HIMA controllers and connection of the PADT.
ETHERNET PORT 01
Eth1 / X3
External Ethernet connection using an RJ-45 interface.
 
ETHERNET PORT 02
Eth2 / X4
External Ethernet connection using an RJ-45 interface.
 
ETHERNET PORT 03
Eth3 / X5
External Ethernet connection using an RJ-45 interface.
 
ETHERNET PORT 04
Eth4 / X6
External Ethernet connection using an RJ-45 interface.
 
 
02 / FIELD CONTEXT
When X-CB 001
becomes critical
The connector board is part of the physical communication path around the HIMax processor environment.
SYSTEM USE
HIMax processor environment
 
COMMUNICATION
Ethernet connections
 
SERVICE ACCESS
PADT connection
Why this part is often checked during a communication-related fault

Because X-CB 001 01 provides the external Ethernet connections associated with the processor module, a problem in the connector-board path can become relevant when controller communication or PADT access is unavailable. In a running safety-control installation, loss of the expected communication path can extend troubleshooting time and may contribute to an operational interruption while the fault is isolated.

 
 
 
 
03 / SERIES RELATIONSHIP
Choose the connector
board by system role
X-CB 001 01
Connector board associated with the X-CPU 01 processor environment; four Ethernet interfaces are provided.
X-CB 001 02
Used with the X-COM 01 communication module and provides Ethernet and fieldbus connection sockets.
X-CB family
Connector-board variants should be matched to the specific HIMax module and interface arrangement required by the installation.
 
AMIKON global automation team
 
AMIKON automation inventory
AMIKON / 20 YEARS IN MOTION
A GLOBAL PARTNER
FOR INDUSTRIAL PARTS
 

Since 2005, AMIKON has developed a global supply network for industrial automation parts and control-system components. Two decades of experience have shaped a practical approach focused on hard-to-source parts, responsive communication and international delivery.

20+
YEARS
GLOBAL
BUSINESS
OPEN
TO REQUESTS
We work worldwide and remain open to every customer requirement.
AMIKON customer service
 
GLOBAL REACH
Automation parts for customers across international markets.
X-CB 001 / REQUEST A QUOTE
Send the part details — we will handle the next step.
EMAIL SALES
 
 
 
 
 
 
 
 
 
 
04 / BUYER FAQ
X-CB 001
before you order
 

The questions below focus on the practical compatibility and replacement concerns that normally matter when a HIMax installation is already in service.

SERIES FOCUS
X-CB 001 01 / X-CPU 01
01
Why is X-CB 001 important when an X-CPU 01 communication path becomes unavailable?
X-CB 001 01 forms the connection layer between the X-CPU 01 environment and its external Ethernet connections. If those physical connections are unavailable, checking the connector-board path can be part of isolating a communication problem.
02
How does X-CB 001 fit into the X-CPU 01 installation rather than acting as a standalone controller?
The connector board and processor module form a functional unit. X-CB 001 01 provides the external Ethernet connections, while the processor module supplies the processing and central system functions.
03
Which X-CB 001 detail should be checked before replacing an existing board?
Confirm the exact variant, module relationship and connector arrangement. X-CB 001 01 is associated with the X-CPU 01 processor environment and uses Eth1–Eth4 as its external Ethernet connections. A different X-CB variant should not be treated as an automatic substitute.
04
Can X-CB 001 be treated as a replacement for the X-CB 001 02 communication-board variant?
No. The variants serve different module environments. X-CB 001 01 is associated with the X-CPU 01, whereas X-CB 001 02 is associated with the X-COM 01 communication module and has a different interface arrangement.
05
What makes X-CB 001 a practical spare when an operating HIMax system needs rapid restoration?
Its role is directly tied to the physical Ethernet connection path of the X-CPU 01 environment. Keeping the exact connector-board variant available can reduce the time spent waiting for a compatible replacement when a communication-path fault has already affected service availability.
05 / RECOMMENDED PARTS
Related automation parts
6SE7033-5GJ84-1JC0 KJ3245X1-BK1 A5E03932844 VE4006P2 6SL3351-6GH34-1AB3
OCR1100 C98043-A7100-L204 KJ4006X1-BF1 6SL3352-6TE41-4AA3 CE3008
A5E00296878 SE4003S2B11 6RY1243-0EA00 KJ1501X1-BC5 6SE7024-7ED84-1HF4
5X00300G02 KJ3221X1-BA3 A5E38979248 6SL3355-6TE35-0AA3 KL4502X1-PA1
KJ3241X1-EA1 CE4100 A5E41929947 6SN1118-0DJ23-0AA2 VE4035S2B1
DELIVERY & TERMS
Delivery 3–5 days
Warranty 12 months
Packing Brand New
Delivery way E-packing / FedEx / EMS / TNT / DHL / UPS
Payment term T/T
QUOTE CHECKLIST
Please include these five details with your inquiry:
Part Number Quantity
Destination Required Date
Machine / System
AFTER-DELIVERY SUPPORT
Return / replacement conditions

Please contact us within 7 days after receiving the item if any issue occurs. Returned products should remain in their original condition and include the specific reason for the return. After the returned item is received and checked, a return or replacement can be arranged where applicable. Return shipping costs are the buyer's responsibility.

06 / CONTACT
Talk to an
automation specialist
For X-CB 001 availability, compatibility checks and quotation requests.
HIMax • X-CB 001 • Industrial Automation Parts
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact