AMIKON LIMITED / INDUSTRIAL CONTROL INSIGHTS
GE FIELD CONTROL SERIES
GE IC670MDL930
Understanding Its Relay Output Design and Role in Industrial Control
Relay output architecture / Field switching / System integration
01 INTRODUCTION
Where Relay Outputs Meet Real-World Control
In an industrial control system, output modules provide the connection between controller logic and field devices. They determine how commands are transferred to equipment such as contactors, indicators, solenoid valves and other controlled loads.
The GE IC670MDL930 is an isolated relay output module in the GE Field Control family. Its combination of Form A and Form C relay contacts supports different switching arrangements within one module, making its output configuration an important consideration when reviewing an existing control system or planning replacement requirements.
|
PRODUCT OVERVIEW
A Flexible Relay Output Arrangement
IC670MDL930 provides eight relay outputs: six Form A normally open points and two Form C changeover points. This arrangement allows the module to accommodate more than one type of field switching requirement.
|
KEY CONFIGURATION
8
Relay output points
6 × Form A 2 × Form C
|
02 TECHNICAL DETAILS
GE IC670MDL930 Product Parameters
Important electrical and operating characteristics for application review.
| Parameter |
Specification |
| Module type |
Isolated relay output module |
| Output points |
8 points: 6 Form A and 2 Form C |
| Rated voltage |
5 / 24 / 125 VDC; 120 / 240 VAC |
| Voltage range |
0–130 VDC; 0–265 VAC, 47–63 Hz |
| Maximum module current |
16 A resistive load |
| Maximum point current |
2.0 A at 5–265 VAC; 2.0 A at 5–30 VDC; 0.2 A at 31–125 VDC |
| Minimum load |
10 mA per point |
| Maximum inrush current |
5 A for 20 ms |
| ON / OFF response |
10 ms maximum each |
| BIU power draw |
313 mA maximum |
| Contact material |
Silver alloy |
| Isolation |
250 VAC continuous; 1500 VAC for 1 minute |
Application note: The stated current ratings vary with voltage and load type. Confirm the actual field load and circuit conditions before installation or replacement.
03 HOW IT WORKS
From Controller Command to Field Switching
The IC670MDL930 works as part of the Field Control system. The controller provides output data through the Bus Interface Unit (BIU), while the module's relay contacts switch the external field circuits.
|
01
Controller
Output command
|
› |
02
BIU
Data interface
|
› |
03
IC670MDL930
Relay switching
|
› |
04
Field Load
Device
|
The BIU supplies module operating power. External AC or DC power is required for the field loads. The module also provides output status LEDs and a power indicator to assist with local status checks.
04 SYSTEM INTEGRATION
What to Check Before Replacing the Module
A replacement decision should consider more than the model number. The output arrangement, field wiring and electrical load all affect whether a module is suitable for the intended installation.
|
A
|
Verify the contact arrangement
Check the six Form A and two Form C output positions against the existing wiring and control logic.
|
|
B
|
Review the field load
Compare AC or DC voltage, steady-state current, inrush current and load type with the applicable output ratings.
|
|
C
|
Confirm the system interface
Check BIU compatibility, module configuration, field wiring and the available installation space.
|
A practical reminder
The IC670MDL930 does not provide isolation between individual points within the same group. Review the circuit grouping and isolation requirements when planning the installation.
05 APPLICATION PERSPECTIVE
Why the Output Configuration Matters
Relay outputs are often used where a controller must switch external circuits while maintaining a clear separation between logic-side control and field-side wiring. The mixed Form A and Form C configuration of IC670MDL930 gives engineers different contact options within one module.
|
Form A
Normally open contact arrangement for switched output circuits.
|
Form C
Changeover contact arrangement providing normally open and normally closed connections.
|
|
06 AMIKON PRODUCT PORTFOLIO
More Brands. More Control Possibilities.
Explore our industrial automation product range across control systems, turbine applications, robotics and monitoring platforms.
|
AMIKON LIMITED
|
HIMA
Black Horse DCS ProSoft Module
ABB
ABB.DCS.AC800F/AC800M
ABB ROBOTICS
ABB Robot Spare Parts, KUKA Robot Spare Parts
ROCKWELL
(AB) Rockwell ICS Triplex trusted system
TRICONEX
TRICONEX/TRICON Card
WOODWARD
WOODWA Woodward RD9907-164/9907-162/9907-165, 9907-167
GE
GE Gas Turbine Spare Parts IS200 DS200 IS215 DS215
DEH
DEH Control Card Steam Turbine Spare Parts
YOKOGAWA
Yokogawa CS3000 Series CP451-10 AAI543 AAI143 AAR145 CP345
BENTLEY
Bentley 3500 Series Monitoring System Card/Pre-processor/Sensor
EMERSON
Emerson DeltaV Series CSI 6500/Philips/epro Monitoring Card/Pre-processor/Sensor
| INDUSTRIAL AUTOMATION PARTS |
A broad range of brands and systems |
07 FAQ
GE IC670MDL930 – Common Questions
Q1. What type of module is the GE IC670MDL930?
It is an isolated relay output module in the GE Field Control family, designed to switch external field circuits through relay contacts.
Q2. How many output points does the GE IC670MDL930 have?
It has eight relay output points: six Form A normally open points and two Form C changeover points.
Q3. Can the GE IC670MDL930 switch both AC and DC loads?
Yes. Its specified voltage ranges include AC and DC applications. The permitted current depends on the voltage and load conditions, so check the ratings for the intended circuit.
Q4. Does the GE IC670MDL930 require an external field power supply?
Yes. The BIU provides module operating power, while an external AC or DC source is required to supply the field loads.
Q5. What should be checked before replacing a GE IC670MDL930?
Verify the module model, output contact arrangement, field voltage, load current, wiring, BIU compatibility and system configuration before installation.
08 CONCLUSION
A Closer Look at the GE IC670MDL930
With eight relay output points and a combination of Form A and Form C contacts, the GE IC670MDL930 serves a specific switching role within the Field Control platform. Understanding its electrical ratings, interface requirements and field wiring arrangement helps support more informed maintenance and replacement decisions.
AMIKON LIMITED / CONNECT WITH OUR TEAM
Need Help with GE IC670MDL930?
Contact our sales team for product enquiries, availability checks and assistance with industrial automation spare parts.
|
EMAIL
Send your product enquiry
|
PHONE / WHATSAPP
Contact our sales team
|
Sales Manager: Miya Zheng
AMIKON LIMITED
Industrial Automation Parts | Control System Components