Honeywell DCS System

BENTLY NEVADA

Home Brands BENTLY NEVADA

BENTLY NEVADA 9200-01-02-02-00 Two-wire moving-coil velocity transducer

BENTLY NEVADA 9200-01-02-02-00 Two-wire moving-coil velocity transducer

 
 
 
BENTLY NEVADA / SEISMOPROBE
BN · 9200
9200-01-02-02-00
TWO-WIRE VELOCITY SEISMOPROBE
 
A two-wire moving-coil velocity transducer for absolute vibration measurement, configured with a low minimum operating frequency, side connector and circular stud base.
4.5 Hz  ·  Side Mount  ·  1/4-28 UNF
CONFIGURATION / 01 · 02 · 02
MINIMUM OPERATING
4.5 Hz
270 CPM
CONNECTOR
SIDE MOUNT
MOUNTING BASE
CIRCULAR
1/4-in 28 UNF stud
AMIKON LIMITED
We have a wide range of brands and products for various industries, we provide services to tens of thousands of customers around the world.
✦ MIYA ZHENG ✉ sales@amikon.cn ◉ 86-18020776792
ABSOLUTE VIBRATION / MOVING-COIL TECHNOLOGY
BENTLY NEVADA
9200 SEISMOPROBE
PRODUCT TECHNICAL SYSTEM AMIKON CONTACT FAQ MODELS
 
 
 
 
 
 
 
 
 
MACHINERY VIBRATION / VELOCITY TRANSDUCTION / 9200 SERIES
9200-01-02-02-00
Two-wire moving-coil velocity transducer for absolute bearing-housing, machine-casing and structural vibration measurement.
FIELD A
01
4.5 Hz / 0 ±2.5°
FIELD B
02
Side Mount
FIELD C
02
1/4-28 UNF Stud
FIELD D
00
No Approvals
MOVING COIL SELF-POWERED TWO-WIRE
BN / 9200 / 01-02-02-00
 
01 / PRODUCT IDENTITY
A direct path
from motion
to velocity
 

The Bently Nevada 9200 Seismoprobe is a two-wire velocity transducer based on moving-coil technology. It is designed to measure absolute vibration of bearing housings, machine casings and structures.

The moving-coil construction produces a voltage directly proportional to vibration velocity. Because the transducer does not require external power, the 9200 can be used for continuous monitoring installations as well as periodic measurements with suitable test or diagnostic instruments.

For the exact 9200-01-02-02-00 configuration, the ordering sequence combines a 0 ±2.5° mounting-angle calibration with a 4.5 Hz minimum operating frequency, a side-mounted connector, a circular 1/4-28 UNF stud mounting base and a no-approval option.

 
 
 
SENSITIVITY
20 mV/mm/s
500 mV/in/s ±5%
FREQUENCY
4.5–1000 Hz
+0 / -3 dB typical
TEMPERATURE
-29 to +121°C
9200 operating/storage
WEIGHT
300 g typical
10.5 oz typical
 
 
02 / TECHNICAL BLUEPRINT
9200-01-02-02-00 / Exact Configuration
Every suffix position has a defined mechanical or electrical role.
A / Mounting Angle + Minimum Frequency
01 0 ±2.5° / 4.5 Hz (270 cpm)
Role Defines the specified mounting-angle range and the minimum operating frequency.
B / Connector
02 Side Mount
Role Defines the connector arrangement used by this 9200 configuration.
C / Mounting Base
02 Circular; 1/4-28 UNF stud
Mechanical interface Circular mounting base with 1/4-28 UNF stud.
D / Agency Approval
00 No Approvals
Selection role The 00 suffix indicates that no agency approval option is selected.
 
03 / PERFORMANCE FIELD
Signal Characteristics
Sensitivity 20 mV/mm/s (500 mV/in/s), ±5%
Calibration load 10 kΩ, terminal A to B
Temperature coefficient 0.2% / °C
Coil resistance 1.25 kΩ ±5%
Locked-coil inductance 125 mH typical
Frequency response 4.5 to 1000 Hz, +0 / -3 dB typical
Dynamic displacement 2.54 mm peak-to-peak maximum
Amplitude linearity ±5%, 0.01 to 5.0 in/s at 100 Hz
Shock resistance 50 g peak along non-sensitive axis
Transverse sensitivity ±10% maximum at specified test condition
Output polarity
Pin A goes positive with respect to Pin B when the transducer case velocity is toward the connector.
04 / INSTALLATION ENVELOPE
Mechanical
and environmental
parameters
The 9200 is designed as a casing-mounted velocity measurement device. Installation quality affects amplitude and frequency response, so the mounting point and mechanical interface should be matched carefully.
Operating / storage temperature -29°C to +121°C
Relative humidity Up to 95%, noncondensing
Maximum use altitude 2000 m / 6,561 ft
Case material Anodized aluminum A204
9200 gasket Neoprene
Typical diameter 41 mm / 1.6 in
Typical height 102 mm / 4 in, depending on connector option
Installation focus
The sensor should be mounted on the bearing housing or machine casing at a location that transmits meaningful machine vibration. Improper installation can reduce amplitude or frequency response or produce signals that do not represent actual machine vibration.
05 / SERIES RELATIONSHIP
9200 Seismoprobe Family Architecture
The model suffix changes the installation interface and operating envelope.
Configuration 9200-01-02-02-00 9200-03-02-02-00 74712-01-02-02-00
Family 9200 Seismoprobe 9200 Seismoprobe 74712 high-temperature version
Minimum frequency 4.5 Hz 4.5 Hz 4.5 Hz
Mounting-angle option 01 / 0 ±2.5° 03 / 90 ±2.5° 01 / 0 ±2.5°
Temperature -29 to +121°C -29 to +121°C -29 to +204°C
Use distinction Low-frequency 9200 configuration Different calibrated mounting angle High-temperature application
Why the full part number matters
The 9200 family contains several mounting-angle, connector, mounting-base and approval combinations. A replacement should therefore be matched by the complete suffix rather than by the family name alone.
06 / CONTACT
Let's match the exact
9200 configuration.

For replacement or project requirements, please provide the complete part number, quantity, destination, required date and application details when necessary.

SALES MANAGER
Miya Zheng
EMAIL
sales@amikon.cn
Commercial Details
Delivery: 3–5 days
Warranty: 12 months
Packaging: Brand New
Delivery: E-packing / FedEx / EMS / TNT / DHL / UPS
Payment Term: T/T
INQUIRY FIELDS Part Number   |   Quantity   |   Destination   |   Required Date   |   Machine / System
Return & Replacement
1. Please contact us within 7 days if you have any question after you receiving the items.
2. The returned items has to be in its original condition, specific reason for the return, we will issue a return or replacement for your order after we received the returns.
3. The buyer is responsible for all the shipping cost incurred.
07 / BUYER QUESTIONS
9200-01-02-02-00 / Selection FAQ
Q1. Why is the 4.5 Hz option important when selecting 9200-01-02-02-00?
The 01 configuration specifies a minimum operating frequency of 4.5 Hz (270 cpm), with the 0 ±2.5° mounting-angle option. This makes the suffix important when the measurement point requires the lower-frequency configuration rather than the 10 Hz or 15 Hz alternatives available within the 9200 family.
Q2. What mechanical detail should be checked before replacing 9200-01-02-02-00?
The mounting-base option is 02, which specifies a circular base with a 1/4-28 UNF stud. A replacement should therefore be checked against the existing mounting interface rather than selecting a 9200 by family name alone.
Q3. Does 9200-01-02-02-00 require an external power supply at the transducer?
No. The 9200 uses a two-wire moving-coil design and does not require external power for the transducer itself. Its output voltage is directly proportional to vibration velocity, which also makes the Seismoprobe suitable for periodic measurements with appropriate diagnostic equipment.
Q4. Can 9200-01-02-02-00 be selected for a side-access installation?
Yes. The second field, 02, is the Side Mount connector option for the 9200 ordering structure. This should be matched to the physical cable and connector orientation required by the installation.
Q5. When should 9200-01-02-02-00 be distinguished from the 74712 family?
The main distinction is environmental temperature capability. The 9200 is specified for -29°C to +121°C, while the 74712 is the high-temperature version of the 9200 and is specified for -29°C to +204°C. If the installation temperature exceeds the 9200 range, the high-temperature family must be evaluated instead.
08 / RELATED MODELS
Industrial Automation Selection
A mixed selection across vibration monitoring, PLC, I/O, control and industrial automation systems.
ADV551-P60
330104-00-25-50-02-CN
IC693ACC320A
6EP1935-5PG01
PR6426/000-130
1756-OW16I
140AVI03000
LDO101
9200-03-02-02-00
IC695ETM001-JY
AAV144-SK0
2612602
330103-00-13-10-02-00
1794-IB32
AFV30D-A41262
DR5000
IC693CHS391M
ADV151-P60/D5A00
24954
6GK5204-2AA00-2BD2
25C-D4P0N104
IC694ALG233
AAI835-S50/K4A00
SIP10
MVME6100
IC693ACC302
PW482-50
DR4900
77158-008-51
1756-CNBR
UT55A-140-11-00
WU10-V-S-05
140CPU67160
6ES7322-1BL00-0AA0
AAI835-S50/K4A00
2410212
S2SC70D-SA12010
2711P-RN15S
F3PU16-0N
PT100-385-4WIRE
129716-125-040-15-05
1747-L543
LE4-116-DX1
AXW4A
IC693CHS391
1794-AENT
CNF2122JA12/C
LQV157
IC200CHS022L
1756-ENBT
ADV151-P60/D5A00
ISENH3181
140AVI03000
1786-RPFM
6EP1935-5PG01
AT6400-120V-NSK
IC695ETM001-JY
6GK5204-2AA00-2BD2
MVME147-012A
S57-51-NSK
140CPU67160
AAV144-SK0
330104-10-20-10-02-00
LDO101
IC693ACC320A
6EP1935-5PG01
330104-00-14-05-02-00
DR5000
AMIKON LIMITED
We have a wide range of brands and products for various industries, we provide services to tens of thousands of customers around the world.
BENTLY NEVADA 9200-01-02-02-00  •  9200 Seismoprobe Velocity Transducer  •  AMIKON LIMITED
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Bently Nevada 3500/22M 138607-01 Transient Data Interface Module
Bently Nevada 3500/22M 138607-01 Transient Data Interface Module

The 3500/22M 138607-01 Transient Data Interface (TDI)   is the interface between the 3500 monitoring system and   compatible software (System 1 Condition Monitoring   and Diagnostic software and 3500 System Configuration   software). The TDI combines the function of a 3500/20   Rack Interface Module (RIM) with the data collection   capability of a communication processor such as TDXnet.

Bently Nevada 3500/22M 288055-01 Transient Data Interface
Bently Nevada 3500/22M 288055-01 Transient Data Interface

3500/22M is a Transient Data Interface Module manufactured and designed by Bently Nevada as part of the 3500 Series used for monitoring seismic activity. The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet.

Bently Nevada 3500/33 149986-01 16-Channel Relay Module
Bently Nevada 3500/33 149986-01 16-Channel Relay Module

The 3500/33 16-Channel Relay Module is a full-height module   that provides 16 relay outputs. You can place any number of   16-channel relay modules in any of the slots to the right of the   Transient Data Interface (TDI) Module.   Each output of the 3500/33 16-Channel Relay Module can be   independently programmed to perform voting logic.

Bently Nevada 3500/60 163179-01 Temperature Monitor Module
Bently Nevada 3500/60 163179-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The modules condition these inputs and   compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/60 133811-01 Temperature Monitor Module
Bently Nevada 3500/60 133811-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The 3500/60 133811-01 modules condition   these inputs and compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor
Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor

The 3500/72M Recip Rod Position Monitor meets API 618   requirements for reciprocating compressors. It measures:   l Rod position   l Rod drop   l Hyper-compressor   The four-channel 3500/72M Recip Rod Position Monitor   accepts input from proximity transducers, conditions the   signal to provide dynamic and static position measurements,   and compares the conditioned signals with userprogrammable alarms.   Each channel, depending on how you configure it, typically   conditions its input signal to generate various parameters   called measured values.

Bently Nevada 3500/62 163179-03 Process Variable Monitor
Bently Nevada 3500/62 163179-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Bently Nevada 3500/62 133811-03 Process Variable Monitor
Bently Nevada 3500/62 133811-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 