01 / PRODUCT IDENTIFICATION
3300 XL 25 mm Proximity Probe
|
| Bently Nevada 330851-02-000-040-10-00-05 is a 3300 XL 25 mm proximity probe. Its ordered build uses case option 02, zero unthreaded length, 40 mm case length, 1.0 metre total probe length, no stainless-steel armor and multiple agency approvals. The probe is designed to work with the corresponding 25 mm Proximitor sensor and matched system length. |
INSTALLED FAMILY
3300 XL 25 mm Proximity Transducer System
|
|
+
|
02 / FUNCTIONAL DESCRIPTION
Signal or Power Role in the Installed System
|
| FUNCTIONAL PATH | The 25 mm probe provides a large linear measurement range for turbine differential-expansion and position applications. It forms one calibrated transducer system with the correct 25 mm Proximitor sensor. Probe length and any extension-cable length must equal the total system length selected at the Proximitor sensor. |
|
+
|
03 / TECHNICAL SPECIFICATIONS
Key Configuration Details
|
|
+
|
04 / COMPATIBILITY AND RELATED MODELS
Select by Function, Suffix and Installed Platform
|
|
+
|
05 / MODEL COMPARISON AND REPLACEMENT GUIDE
Replacement Checks Before Shutdown
|
| Identity: match the complete suffix and style. | Connection: verify the base, terminal block, adapter and field wiring. | System fit: confirm platform release, channel behavior and environmental execution. |
| Contact us within seven days if a concern appears after delivery. | Return the item in its original condition with the reason stated. Resolution follows receipt and inspection. | Return-related transport costs are arranged by the buyer. |
|
+
|
06 / TECHNICAL FAQ
Five Checks Buyers Should Complete
|
| 01 |
330851-02-000-040-10-00-05 - What is the most important ordering check?
Match the complete model, suffix code and style with the installed unit; the base model alone is not sufficient.
|
| 02 |
330851-02-000-040-10-00-05 - Can a related model be used as a direct substitute?
Only after channel count, signal type, isolation, termination, environmental execution and supported system release are confirmed.
|
| 03 |
330851-02-000-040-10-00-05 - What should be recorded before removal?
Record slot position, terminal assignment, field polarity, connected base or terminal block, and all visible suffix and style markings.
|
| 04 |
330851-02-000-040-10-00-05 - What should be tested after installation?
Verify seating, wiring, power and diagnostics, then commission each affected channel under controlled conditions.
|
| 05 |
330851-02-000-040-10-00-05 - What should be sent with a quotation request?
Send the full catalog code, quantity, required condition, destination and clear photos of the unit label and front connection area.
|
|
+
|
07 / RECOMMENDED MODELS
Industrial Automation Parts
|
|
+
|
08 / ORDERING INFORMATION
Price, Availability and Delivery Coordination
|



Inventory Products