| ABB / INDUSTRIAL AUTOMATION | OverviewSpecificationsIntegrationRelated ModelsFAQ |
A compact book-style, two-stage EMC/RFI filter for three-phase drive systems. It reduces conducted interference between the drive and the mains while supporting long motor-cable applications.
| OPERATING PROFILE | |
|---|---|
| Product identity | FN258-16/29 / 3BHB011317R0001 |
| Product function | Three-phase EMC/RFI mains filter |
| Rated current | 16 A at 50 C; 17.5 A at 40 C |
| Rated phase-to-phase voltage | 480 V AC |
| Rated phase-to-ground voltage | 277 V AC |
| Operating frequency | DC to 60 Hz |
| Typical drive power | 7.5 kW |
| Leakage current | 18.3 mA at 440 V AC / 50 Hz |
| Power loss | 20 W at 25 C / 50 Hz |
| Filter configuration | Two-stage, three-phase delta |
| Termination | Terminal block; -29 connection format |
| Mounting | Chassis mount |
| Operating temperature | -25 to +100 C |
| Dimensions | 305 x 55 x 142 mm |
| Weight | 1.4 kg |
| Approvals | CSA, ENEC and UR |
| MAINS SIDE Installed between the three-phase supply and the drive input. |
FILTER CORE Two attenuation stages suppress conducted common-mode and differential-mode noise. |
DRIVE SIDE Suited to inverter and power-drive systems, including installations with long motor cables. |
CABINET DESIGN Book-style housing reduces panel width while chassis mounting supports a low-impedance earth path. |
| Q1 | What must match before ordering this filter? Confirm the three-phase line voltage, continuous input current, drive power, connection format and available cabinet space. |
| Q2 | Can the filter be selected only from motor power? No. Drive input current and supply voltage are the primary checks; motor power is a supporting selection value. |
| Q3 | What does the /29 suffix affect? It denotes the connection format used on this FN258 size. The installed cable and terminal arrangement should match. |
| Q4 | Is protective earthing important for EMC performance? Yes. A short, broad and low-impedance chassis connection is essential for effective high-frequency attenuation. |
| Q5 | Can a higher-current FN258 replace this unit directly? Electrical capacity may increase, but dimensions, terminals, leakage current and cabinet layout must also be checked. |
| 81003-438-51-R | A413141 BIU82 | 1KHW001356R0001 P4RX |
| 140DAO85300 | ALR121-S51 S1 | DSQC239 YB560103-CH |
| EPDM 76/DN80/3 | 1KHL015545R0002 O4LE | 1797-IE8NF |
| NFPW442-11 | DSQC256A 3HAB2211-1 | 4L-L4-M2-B1A |
| SNT501-13 | CS-SS-RHR1HE-03 | SPW481-13 |
| SNB10D-213 | 1785-L60B/C | 1784-PKTX |
| 1KHW001223R0002 P4LT | 103147 SAE-14 | TM80125 |
| 11-018-164 | AAT145-S50 S1 | REF615E_D REF615E-D |
| FIO-11 68679079 | VPM-8100LS-000 | 71503-052130 |
| SNT521-53 | NA50-40NAMKNN-CE | 1747-KFC15 |
| EC401-51 | K9634DA K9634DA-01 | ASS9981DE-02 |
| MA40-7073 | 79835-66515 | 2711P-K6C20A |
| RDIO-01 64379216D | E24KN9ZCCM | C98043-A7600-L1 |
| SDV144-S33 S2 | D200175 AP31 | 07KR91 GJR5250000R0151 |
| NFPW442-51 | WMZT3D20T | RAIO-01 64379224F |
| SAI143-H63 S4 | SNT401-53 | NFSB100-S01 |
| 02-681-339 | NFDV551-P11 | 2080-DNET20 |
| 194r-c30-1753 | MSD013A1Y | 4L-E4-C1A-TT |
| NFDV561-P51 | 05V-0070L | DSQC323 3HAB5956-1 |
| 22TA-L4-SS | MSD5AZA1Y | VPM-8100Q-000 |
Send the complete product identity, required quantity, destination and target delivery date for a focused quotation.
CONTACT SALES


Inventory Products


More than 40.000.000 products available and worldwide support