Brand |
Woodward |
|
Model |
5462-758B |
|
Descripution |
28 Channel Discrete Output Mod |
|
Condition |
New |
|
Origin |
USA |
AMIKON LIMITED
20+ Years of Delivering Control System Parts Worldwide
Shop the Largest Inventory of the Rarest Parts
Find what you need. Search our store for parts for ABB, Alstom, Bently Nevada, Emerson, GE, Honeywell, Rolls Entronic, Siemens, Triconex, Westinghouse, and Woodward control systems.
|
|
|
|
Sales manager: Miya zheng ➪ Email:sales@amikon.cn ➪ WhatsApp:86-18020776792
PRODUCT DESCRIPUTION
MODEL 5462-758B 28 Channel Discrete Output Module
ORIGIN USA CONDITION NEW
IN STOCK!!!
|
SPECIFICATIONS |
|
|
Estimated Shipping Size |
2.5 × 24.6 × 26.1 cm |
|
Weight |
0.95 kg |
|
Rack Supply |
24 V DC |
|
Module Consumption |
0.3 A @ 24 V DC |
|
Output Channels |
28 × Isolated Discrete Outputs |
|
Isolation |
500 V DC (Channel-to-Bus) |
|
Operating Temperature |
0 °C to +60 °C |
|
Storage Temperature |
–40 °C to +85 °C |
|
Humidity |
5–95% RH (Non-condensing) |

|
MicroNet Plus and MicroNet Simplex controls |
|
The MicroNet Plus and MicroNet Simplex controls are a 32-bit microprocessor-based digital controllers that are programmable for many types of applications in the control of: |
|
l Gas and Steam Turbines l Gas and Diesel Engines l Hydro Turbines |
|
The MicroNet Controls family provide a flexible system to control any prime mover and its associated processes such as high speed control functions, system sequencing, auxiliary system control, surge control, monitoring and alarming, and station control. The MicroNet platform is available in simplex, redundant, and Triple Modular Redundant (TMR) configurations. This manual covers only simplex and redundant based control configurations. Please refer to manual 26167 for TMR-based control configurations. |
|
The MicroNet Operating System, together with Woodward’s Graphical Application Program (GAP), produces a powerful control environment. Woodward’s unique rate group structure ensures that control functions will execute deterministically at rate groups defined by the application engineer. Critical control loops can be processed within 5 milliseconds. Less critical code is typically assigned to slower rate groups. The rate group structure prevents the possibility of changing system dynamics by adding additional code. Control is always deterministic and predictable. |
|
Dedicated inputs and outputs (I/O) are available onboard for key control signals while distributed I/O can be used for other less critical parameters. |
|
Communications with the MicroNet platform are available to program and service the control as well as to interface with other systems (Plant DCS, HMI, etc.). Application code is generated by use of Woodward’s GAP program or Woodward’s Ladder Logic programming environment. A service interface allows the user to view and tune system variables. Several tools are available to provide this interface (see Engineering and Service Access). Communication protocols such as TCP/IP, OPC, Modbus, and other current designs are included so that the user can correctly interface the control to existing or new plant level systems. |
|
The MicroNet platform is expandable into multiple chassis as required by the system size and will support any mix of I/O, including networked and distributed I/O. The MicroNet control is available in chassis sizes with 6, 8, 12, or 14 VME slots. Each has dedicated power supply and control sections located in a single chassis. The power supply architecture supports simplex or redundant power supplies. |
|
|