ABB / FIELD NETWORK
COMMUNICATION ADAPTER
BCAN-11
3AXD50000033816
CANopen®
ACS380 FIELDbus OPTION
◆ OPTION CODE +K495
|
NETWORK CONNECTION
CANopen Interface
FIELDbus COMMUNICATION
|
AMIKON LIMITED
ASK FOR PRICE
Sales Manager
Miya Zheng
|
||||||||
| ABB / BCAN-11 / CANOPEN | OverviewSpecificationsIntegrationRelated ModelsFAQ |
|
ABB ACS380 CANOPEN INTERFACE
BCAN-113AXD50000033816
|
||
|
CAN
|
Drive-to-Network Bridge
A CANopen interface for compatible ABB ACS380 drives. The module uses screw terminals and connects the drive to a linear CAN bus for cyclic control, status and operating-value exchange. REQUEST A QUOTE |
+K495
|
|
Sales manager: Miya zheng | sales@amikon.cn | WhatsApp: 86-18020776792
|
||
|
01
Product
BCAN-11
|
02
MRP code
3AXD50000033816
|
03
Protocol
CANopen
|
|
04
Drive option
+K495
|
05
Drive family
ACS380
|
06
Physical interface
X1 screw terminals
|
|
07
Network medium
CAN bus
|
08
Topology
Linear trunk
|
09
Node setup
Unique node address
|
|
10
Bus setup
Common bit rate
|
11
Termination
Both physical ends only
|
12
Primary task
Cyclic drive control and monitoring
|
| 120R | CANopen controller Network coordinator |
— | BCAN-11 ACS380 drive node |
— | Additional node Unique address |
120R |
Use one linear trunk, a common bit rate and unique node addresses. Fit termination only at the two physical ends and preserve CAN conductor polarity and shield continuity.
|
CAN / Q01
Can ABB BCAN-11 3AXD50000033816 replace an FCAN-01 module directly?
No. BCAN-11 is an ACS380 CANopen option with an X1 screw-terminal interface. FCAN-01 belongs to another adapter family and uses a different physical connection and configuration path.
|
CAN / Q02
Which drive should be confirmed for ABB BCAN-11 3AXD50000033816?
Confirm an ACS380 configuration that supports option +K495. Also verify the drive software level and the exact option position before ordering.
|
|
CAN / Q03
What network settings are essential for ABB BCAN-11 commissioning?
Every node needs a unique address, all nodes must use the same bit rate, the controller must use the intended CANopen profile and the physical bus ends must be terminated.
|
CAN / Q04
How should the ABB BCAN-11 bus be wired?
Use a linear CAN trunk with suitable shielded cable. Avoid star branches, keep stubs short, maintain conductor polarity and install termination only at the two physical ends.
|
|
CAN / Q05
What should be backed up before replacing ABB BCAN-11?
Record node address, bit rate, drive profile, process-data mapping, heartbeat or guarding behavior, fault response and the exact terminal conductor order.
|
CAN / Q06
How is ABB BCAN-11 validated after installation?
Check drive recognition, bus state and error counters; confirm control and status words, command values, actual values, timeout behavior and safe recovery after a network interruption.
|
| PLX51-HART-4I | 6GK1105-2AD10 | 6ES7132-4BF00-0AA0 | 3HNA018784-001 | 3HAC5954-1 |
| 3500/20 125744-02Z | F3236 984323602 | eTOP11-0050 | LNS-W03 | DA70 201851-01 |
| HMCP003ADC | 6ES7155-5BA00-0AB0 | LV434128 FDM128 | ML7421B1023 | XL31K5A4-20 |
| R-Myra-300-P | FC96TX | USI-0001 | F880-CL-PS-E F880 | 55QM 082H3078 |
| XCPBDP00 | VS-4450 | 2198-D057-ERS4 | 2198-S086-ERS3 | A5E02599492003 |
| 6EP3333-7SB00-0AX0 | 80190-480-01-R | SPTM-6VLC3 | TD-36AV 3618-0101 | MXT-1 70152-283 |
| 80190-478-51 | 3HAC026253-001 | IC670TBM002 | IC670TBM001 | 3HAC033203-001 |
| 9907-028 | DTTN-020-N000-N | 6ES7510-1DJ01-0AB0 | PFM FLEX | MI-B501AP-IV |
| 22B-B017N104 | 509-AOA | ESC-PLATINE | P7620C0025B | 3.3563.024/61 |
| NXC1 NetAXS-123 | ML7425A6008 | IC695RMX128 | 100-D115KF11 | 22A-A1P5N104 |
Send the ACS380 type code, option marking, node settings, terminal photograph, quantity and delivery target.
SEND YOUR REQUIREMENT