| TRICONEX / 3564E | PRODUCTSYSTEM FITSUPPLYFAQMODELS |
| A SINGLE INPUT ARCHITECTURE WITH A PRECISE SYSTEM ROLE | ||||||
|
DIGITAL INPUT
64
COMMONED POINTS
15–30 VDC
|
Triconex
3564E
A 24 VDC single digital-input module associated with the Tricon 3564 hardware family. Optically isolated field states pass through intelligent I/O controllers to the triplicated I/O bus. The supplied 3564E marking, chassis generation, termination assembly and revision must be confirmed together.
|
|
||||
| 64 INPUT POINTS Commoned discrete inputs |
15–30 VDC RANGE Recommended field voltage |
36 VDC MAX Maximum applied voltage |
| < 2 MS DELAY Both switching directions |
1500 VDC ISOLATION Minimum point isolation |
< 10 W LOGIC Module logic power |
| CHECK PRICE + LEAD TIME Complete code, revision and quantity. |
EMAIL MIYA | WHATSAPP +86 18020776792 | Sales Manager Miya Zheng |
| 01 | SIGNAL ENTRY | The module accepts 64 commoned 24 VDC field states. Each point has an On/Off indicator, while module-level indicators report Pass, Fault, Active and Power conditions. |
| 02 | THRESHOLD WINDOW | Off-to-On is 12 VDC typical and 15 VDC worst case. On-to-Off is 8 VDC typical and 6 VDC worst case, with approximately 4 VDC typical hysteresis. |
| 03 | FIELD LOADING | Nominal turn-on current is 2 to 3 mA and nominal input impedance is above 3.0 kΩ. Sensor leakage and contact behavior must remain inside this operating window. |
| 04 | AVAILABILITY POSITION | The single input architecture is fail-safe but does not provide the availability level of a TMR digital input. Hot-spare use requires the application to account for the documented switch-over behavior. |
| 05 | PHYSICAL MATCH | Dark-red identification, mechanical slot keying, compatible field termination and the complete product label are all part of the replacement decision. |
|
GATE 01
POINT DENSITY
64 commoned inputs
|
→ |
GATE 02
ELECTRICAL WINDOW
15–30 VDC recommended
|
→ |
GATE 03
ARCHITECTURE
Single and fail-safe
|
→ |
GATE 04
PHYSICAL FIT
Keying and termination
|
| MODEL | POINTS / VOLTAGE | ARCHITECTURE | SELECTION BOUNDARY |
| 3564 / 3564E | 64 / 24 VDC | Single | Target identity; verify the complete marking. |
| 3503E | 32 / 24 VAC/VDC | TMR | Different density and redundancy. |
| 3504E | 64 / 24–48 VDC | TMR | Same density does not mean interchangeability. |
| 3505E | 32 / 24 VDC | TMR low threshold | Different threshold and self-test behavior. |
|
AMIKON SUPPLY
A Clear Route from Request to Dispatch.
Responsive communication, careful order matching and coordinated international delivery for current and discontinued automation parts.
|
|
| QUALITY | RELIABILITY | TRANSPARENCY | SUPPORT |
| CONTACT MIYA FOR AVAILABILITY Complete code, revision and quantity. |
EMAIL MIYA | WHATSAPP +86 18020776792 | Sales Manager Miya Zheng |
| ORDER CARE | Contact us within seven days if a concern appears after receipt. | Keep the item in its original condition and state the reason. Resolution follows receipt and inspection. | Return-related shipping costs are paid by the buyer. |
| 01 | 3564E: What must be matched before ordering? | Match the complete front and side labels, assembly revision, chassis generation, slot keying, field termination and configured spare arrangement. |
| 02 | 3564E: Can 3504E replace 3564E because both have 64 points? | No. The 3504E is a high-density TMR input with a different voltage and redundancy architecture. Equal point count does not establish electrical or system compatibility. |
| 03 | 3564E: How does the single architecture affect availability? | The 3564 architecture is fail-safe but does not provide the same availability as a TMR input. If a hot spare is configured, the application must tolerate the documented switch-over behavior. |
| 04 | 3564E: Which field values should be checked? | Confirm the 15–30 VDC recommended input range, sensor leakage, switching thresholds, common return arrangement and the matching termination assembly. |
| 05 | 3564E: What should be supplied for a quotation? | Provide the complete 3564E marking, hardware revision, quantity, destination, required condition and clear photographs of the front, side and connector area. |
| LP470-35.5 | EM-07K | WT-40-282-A | 1394C-SJT22-A |
| 4007000 .7000 | CL310 SD28H | 847375-0038 | 194r-c30-1753 |
| 02-707-422 | AAP135-S50 | 33918-603 | AAI841-H50 |
| SL-V31F | ADV551-P60 | LTST-C930GKT | X-CB 008 |
| 15M3601 15M36 | 87302T 1-1/4-8 | Hammond 155206 | KP3ALSD510 |
| 8MX50S62-2517 | TS500R | STRN-CRK-01 | 02-681-339 |
| 5711101PF | 05V-0070L | AAI135-S50/K4A00 | SNB10D-425-CU2N |
| AG-DRT11-06 | 49SPL0HWF | P0916KF-0B | B9544GA |
| 6RY1803-0DB02 | 100501-K | LMB24-SR | CT485B |
| HF9HA-1B | 4-HESI 5X20 | A6750022C | 20-1702B |
| 3RT5045-1BB40 | MC-9 13/16-16 | CEX-150-0026 | 802044 802060-A1 |
| MBDC050-050101 | S2SC70D-SA11010 | 3HAC047584-002 | 17L65104S-LW4 |
| 11-018-164 | 3HAC057542-003 | 41764646WC | 2094-BM03-M |
| 110-282 | IS220UCSAH1A | DNA-040K-22B | 3RU2116-1AB0 |
| 7027C A50G00021 | EZL0102-01 | 11-312E-06-HP | LP470-49 |
| MORE RELATED MODELS - CONTACT US Complete code, revision and quantity. |
EMAIL MIYA | WHATSAPP +86 18020776792 | Sales Manager Miya Zheng |



Inventory Products


More than 40.000.000 products available and worldwide support