| SCHNEIDER ELECTRIC / ALTIVAR PROCESS | OverviewSpecificationsIntegrationFAQ |
|
ALTIVAR PROCESS ATV900 / FRAME 6
ATV930C16N4C
160 kW process variable speed drive
Designed for three-phase synchronous and asynchronous motors, this ATV930 combines motor control with embedded process monitoring, power measurement, asset protection and Ethernet-based connectivity. Order configuration: 400-480 V, IP00, wall-mounted format, without integrated braking unit.
|
|
| Sales manager: Miya zheng | ✉ sales@amikon.cn | ☎ WhatsApp: 86-18020776792 |
|
ELECTRICAL PROFILE
Power stage and duty ratings
Normal-duty and heavy-duty values must be matched to motor load, overload profile, cabinet cooling and braking requirements. |
|
|
⇅ Motor control
Asynchronous, permanent-magnet and synchronous-reluctance profiles
|
◉ Connectivity
Embedded Ethernet and two-wire RS-485 with Modbus services
|
⚠ Safety
STO, SS1, SLS and safe brake management capabilities
|
|
01
400-480 V supply
|
⟶ |
02
ATV930C16N4C
|
⟶ |
03
Process motor
|
Ethernet
RS-485 I/O |
| No integrated braking unit. Evaluate VW3A7105 and external resistor requirements for regenerative stopping duty. | Frame 6 installation requires correct airflow, clearances, cable lugs and enclosure engineering. | Embedded energy and process functions support operating-cost and asset-condition review. |
| Sales manager: Miya zheng | ✉ sales@amikon.cn | ☎ WhatsApp: 86-18020776792 |
|
|
AMIKON / SINCE 2005
Twenty years of industrial automation supply
Amikon supports global manufacturers and system integrators with automation components for PLC, HMI, DCS, industrial PC and variable-speed-drive installations. 12-month warranty
Prompt quotation response
International delivery coordination
|
|
| Does ATV930C16N4C include a braking unit? | No. For regenerative stopping, review the external VW3A7105 braking unit and resistor sizing against motor inertia, cycle time and braking energy. |
| Which duty current should be used for ATV930C16N4C? | Use 302 A for low-overload duty or 250 A for high-overload duty only after checking the load torque and required 60-second transient current. |
| What enclosure work is required for ATV930C16N4C? | Its IP00 form requires a suitable cabinet, airflow, clearances, touch protection and environmental control. The final enclosure rating comes from the completed installation. |
| Can ATV930C16N4C control a permanent-magnet motor? | Yes, the ATV930 supports permanent-magnet and synchronous-reluctance profiles as well as asynchronous motors. Confirm motor data and commissioning method. |
| What should accompany an ATV930C16N4C inquiry? | Provide line voltage, motor plate values, duty type, braking cycle, cabinet conditions, communication protocol and required safety functions. |
| MTN631619 | XP10BKB/DC | DIN-AP2 | EM-07K | SB-DIM4c3A-DN |
| 700-K40E-ZY | DAA2-7525E | STD924-F1H-00000-DE | GEA 0000000206 | S-292E-SDI1-FS |
| SMART-1 | OD7003F0A01120000 | NC5MD-LX | AM-1MWQAMX | 6ES7513-1AL02-0AB0 |
| 6ES7155-5AA01-0AB0 | 6ES7531-7KF00-0AB0 | SNAT7261INT | 330881-28-04-150-00-02 | 190501-00-00-04 |
| 200350-09-00-01 | 1783-US6T2F | Honeywell SC-UMIX01 | DRB200 | RZ-TMS |
| CS1-M | IFR-2975 | 7000-845-SE | 7865FD | R2670B |
| FVT4014M | 6SE7041-8EK85-1HA0 | X20CP1483 | NPACON4S | MMDS-CLC |
| ICX35-HWC-E | OPTO22 SNAP-LCM4 | 396P-02-12-55 | 3900-2-10 | KJ2201X1-BA1 |
| DX8210-4100 | IMX-M 102G | ABB 001-1004-03 | VP-T537 | HVBNET16TO |
| ESP-00 | TXR-320 | 3701/55 | 103 342/4 R1J | SAFI2 |
|
Confirm drive duty, enclosure and braking architecture
Report concerns within seven days of receipt. Returned goods must remain in original condition and include the return reason. Return freight is paid by the buyer.
|
REQUEST ATV930C16N4C Configuration and availability support |
| Sales manager: Miya zheng | ✉ sales@amikon.cn | ☎ WhatsApp: 86-18020776792 |



Inventory Products


More than 40.000.000 products available and worldwide support