
|
FIELD INSTRUMENTATION / SIGNAL INTERFACE
PLX51-HART-4O
4-Channel HART Output Module
Connect HART-compatible field equipment, including valve positioners, to supported industrial Ethernet networks. The module combines four-channel HART communication with analog 4–20 mA signals, allowing process values and HART device communication to work within an appropriate control architecture.
|
FIELD SIGNAL PATH
Choose the network mode and device topology according to the intended controller architecture.
|
| 01 / HART & Analog | Four HART communication channels support analog 4–20 mA signals for compatible field devices. Typical use includes connecting valve positioners and exchanging process-related data through the supported network interface. |
| 02 / Network Modes | Supports EtherNet/IP, Modbus TCP/IP and DNP3 over TCP/UDP. EtherNet/IP supports direct integration of HART devices into a compatible Rockwell Automation Logix I/O tree. Point-to-multipoint operation is supported for EtherNet/IP with up to five devices; confirm the required topology before installation. |
| 03 / Electrical & Physical | Supply range: 12–28 VDC. Enclosure rating: IP20, NEMA/UL Open Type. Operating temperature: −20°C to 70°C. Dimensions (H × W × D): 101 × 22.5 × 120 mm. Power demand depends on the attached field devices. |
| MODEL | CORE FUNCTION | SELECTION ADVANTAGE |
| PLX51-HART-4O | Four-channel HART output and 4–20 mA signal integration | Best suited when HART-compatible field equipment must connect to supported Ethernet protocols. |
| PLX31-MBTCP-MBS4 | Modbus TCP/IP to four-port Modbus serial | Better suited to installations with existing serial Modbus instruments and multiple serial branches. |
| PLX32-EIP-MBTCP-UA | EtherNet/IP + Modbus TCP/IP + OPC UA Server | Designed for multi-protocol data exchange when OPC UA client access is part of the application. |
|
AMIKON / INDUSTRIAL AUTOMATION PARTS
Fast Response for Critical Parts Requirements
AMIKON works to source new and discontinued industrial automation parts for customers across different industries. Our focus is reliable supply, clear communication and efficient order handling to help customers reduce downtime and keep operations running.
We value quality, reliability, trust, innovation and customer service, aiming to build long-term partnerships through consistent support and practical purchasing assistance.
|
Sales manager: Miya zheng
✉ EMAIL AMIKON ☎ PHONE / WHATSAPP
86-18020776792
|
|
CUSTOMER SERVICE
Quick Response Support
Responsive communication for urgent requirements.
|
QUALITY FOCUS
High-Quality Parts Supply
Careful order handling for industrial requirements.
|
GLOBAL DELIVERY
International Delivery on the Day
Focused on efficient delivery and reduced downtime.
|
| Q1. Can PLX51-HART-4O connect HART valve positioners to an Ethernet-based controller? | Yes. It is intended for HART-compatible field devices such as valve positioners and supports EtherNet/IP, Modbus TCP/IP and DNP3 Ethernet connectivity. Confirm the required protocol, device mode and controller integration method before ordering. |
| Q2. What should be checked when replacing PLX51-HART-4O with another HART module? | Match the number of HART channels, 4–20 mA signal requirements, protocol, field-device topology, supply voltage, terminal wiring and controller configuration. A four-channel HART output module is not automatically interchangeable with a HART input module. |
| Q3. Does PLX51-HART-4O support point-to-multipoint communication? | Point-to-multipoint is supported for EtherNet/IP with a maximum of five devices. Point-to-point network operation is supported with EtherNet/IP, Modbus TCP/IP or DNP3 over TCP/UDP. Confirm the intended arrangement and field-device compatibility. |
| Q4. What power supply and installation conditions does PLX51-HART-4O require? | The module requires 12–28 VDC and has an IP20, NEMA/UL Open Type enclosure. Its operating temperature range is −20°C to 70°C. Allow for the additional power demand of connected field devices and install it within a suitable protected enclosure. |
| Q5. What information helps confirm PLX51-HART-4O availability and application fit? | Provide the full part number, quantity, destination, target delivery date, controller platform, selected Ethernet protocol and the number/type of HART field devices. This helps verify whether the requested model fits the intended network arrangement. |
| KC3010X1-BK1 | 7400166-380 | CC-PDOB01 | PR9268/617-100-CNS |
| IC660BBA021 | F3 DI 16 01 | F3000-ELEMENT-Y | MVI56E-MNETCR |
| IC200CPU005-CE | 7400150-270 | 80190-560-02-R | CC-PCNT02 |
| MVME147-022 | IS220PCLAH1A | CC-ZHR041 | 160-BA10NSF1 |
| MVI56E-MNETXT | HW1B-V4F02-R | IC693MDL940 | 9904-575 |
| ACC-T180350 | PR9268/203-100 | A2SAT105-S000 | KJ4001X1-CH1 |
| IC660BBA023 | CC-PAIL51 | 160-AA02NSF1 | IC695CPE330-ABAN |
| MVI56E-MNETR | FC-UGAO01 | W4000-ELEMENT-Y | F8652X |
| MVME2303 | MVI56E-MCMR | AR20K-N02BG-ZB | IC694MDL660-BC |
| IC694DSM324-BE | F3 DO 8 01 | KJ3225X1-BA2 | 1305-BA04A |
| 25A-D1P4N104 | F3 DIO 24/16 01 | 0018A6899 | 2071-A15 |
| EC402-51 | F8621A | MVME147-012A | CC-PCF901 |
| 8440-2085 | 330980-71-CN | F8651X | 5501-367 |
| 80190-300-01-R | MVME2304 | 8750-CA-NS | 25A-D2P3N104 |
| A6740-12-N | PR9268/207-100 | 330180-50-00 | MVI56E-GSC |



Inventory Products


More than 40.000.000 products available and worldwide support