HONEYWELL / INDUSTRIAL AUTOMATION
FTA-T-01Fail-Safe Digital Input FTA
Field termination assembly for FSC input wiring
A field-side interface between FSC system interconnection cables and external digital input wiring. Three fused groups provide screw-terminal access for twenty-four fail-safe input channels. |
![]() |
| 24 channels | 3 groups x 8 | 24 / 48 / 60 Vdc |
| Sales manager: Miya zheng | EMAIL sales@amikon.cn | WHATSAPP 86-18020776792 |
| Hardware role | Fail-safe digital input field termination assembly |
| Input arrangement | 24 channels in 3 groups of 8 |
| Field voltages | 24 / 48 / 60 Vdc applications |
| Group protection | 250 mA time-delay fuse in each common positive group |
| SIC connectors | 1A, 1B and 2A |
| Field connection | Screw terminals |
| Maximum conductor | 2.5 mm2 / AWG 14 |
| Strip length | 7 mm |
| Terminal torque | 0.5 Nm |
| DIN rail | TS32 or TS35 x 7.5 |
| Dimensions | 145 x 70 x 65 mm |
| Used rail length | 146 mm |
| Approvals | CE and UL |
| Sales manager: Miya zheng | EMAIL sales@amikon.cn | WHATSAPP 86-18020776792 |
| Model | Position | Main difference | Use when |
|---|---|---|---|
| FTA-T-01 | Main model | 24 fail-safe digital inputs; screw terminals | Existing FSC wiring uses 24/48/60 Vdc inputs and direct field termination. |
| FTA-E-01 | Connector variant | Comparable 24-channel input function with ELCO field connection | The cabinet harness is built around E56 connector termination. |
| FTA-T-21 | Later alternative | Alternative for obsolete FTA-T-01 applications | A controlled migration has verified cable, field voltage and channel mapping. |
|
|
AMIKON LIMITED
Listen. Think. Solve.
Global supply support for PLC, DCS, safety, drives, turbine control and condition-monitoring hardware. ◆ Multi-brand automation inventory
◆ Multilingual order support
◆ Rapid international delivery network
|
| Q1 | What must match before buying HONEYWELL FTA-T-01?
Confirm the exact model, 24/48/60 Vdc input circuits, 24-channel map, SIC cable arrangement, screw terminals and DIN-rail space.
|
| Q2 | Does HONEYWELL FTA-T-01 process the safety logic itself?
No. It terminates field inputs and connects them through SIC cables; the associated FSC input hardware performs system-side processing.
|
| Q3 | How are HONEYWELL FTA-T-01 channels protected?
The 24 inputs are divided into three groups of eight, with a 250 mA time-delay fuse in the common positive path of each group.
|
| Q4 | Can HONEYWELL FTA-T-01 be replaced by FTA-E-01 without rewiring?
Not as a direct terminal-for-terminal exchange. FTA-T-01 uses screw terminals while FTA-E-01 uses an ELCO connector arrangement.
|
| Q5 | What should be checked when HONEYWELL FTA-T-01 arrives?
Inspect SIC connectors 1A, 1B and 2A, terminal screws, fuse holders, rail clips, channel markings and the circuit board for heat or handling damage.
|
| IG5398 | QSNE-4S10-D | NE8MC6-MO | TPSN-50AB | M71-R6000 |
| WIQ81163 | CLNXEHS26D100A | 10P57700005 | CCS-CURD | T8431 |
| VX-3004F | MA-8000 | KFD2-SL-Ex1.48 | PD-9001GO | 1SVR427030R0000 |
| 6EP1961-3BA21 | HMIZSUSBB | KL4032 | EAOM-19 | AD-155A |
| QMX2.P33 | IFP-2100HV | FC-SDIL-1608 | C10-12010 | 1VCR017053G0006 |
| A2SAT105-S000 | FU20-05-T1-NPT | UT55A-001-11-00 | CP471-01 | F3236 |
| VLF-250-01 | 3027R002 SF6 | M3SRG0400 | PR9268/200-000 | PR9268/207-100 |
| 3500/42M 135489-01 | 5204-DFNT-PDPMV1 | NV350 K30017F | M5100-AC-IS | 330102-00-12-10-01-05 |
| IS220PCLAH1A | 8750-CA-NS | IS210HSLAH1A | ESM-30B | HIEE300698R0001 |
| CPU2-640PCB | MTL831C | HD-MD4X1-4K-E | 750-430 | MK5154 |
| 01 Contact within 7 days Send order details, photographs and a concise description. |
02 Keep the item complete Approved returns retain original condition, packaging and accessories. |
03 Inspection and outcome Return or replacement follows receipt and inspection; return shipping remains the buyer's responsibility. |
| Sales manager: Miya zheng | EMAIL sales@amikon.cn | WHATSAPP 86-18020776792 |



Inventory Products


More than 40.000.000 products available and worldwide support