
|
ANYBUS COMMUNICATOR
HMS AB7000-CSerial Master to PROFIBUS GatewayConnects RS-232, RS-422 or RS-485 equipment to a PROFIBUS control system without changing the serial device hardware.
|
|
| Gateway direction | Serial master/client to PROFIBUS DP slave |
| Serial interfaces | RS-232, RS-422 and RS-485; Modbus RTU and configurable transactions |
| PROFIBUS process data | Up to 244 bytes input and 244 bytes output; 416 bytes total |
| Serial data size | Up to 512 bytes input and 512 bytes output |
| Power and current | 24 V DC +/-10%; typically 100 mA, 300 mA maximum |
| Mechanical | 120 x 75 x 27 mm; IP20; 35 mm DIN-rail mounting |
| Environment | 0 to 55 deg C; 0% to 95% RH non-condensing; altitude up to 2,000 m |
| 01 Serial device
Record interface type, baud rate, parity, stop bits, node behavior and command sequence. |
02 PROFIBUS master
Confirm DP network, station address, cyclic I/O length and matching configuration data. |
03 Cabinet fit
Provide 24 V DC, DIN-rail space, shielding, grounding and access to both D-sub connectors. |
![]() |
Professional automation sourcingExperienced support for scarce and discontinued automation components, responsive order tracking and worldwide delivery coordination. More expertise: multilingual support and clear commercial handling. More choice: broad coverage across PLC, DCS, HMI, drives and industrial communication. Faster action: same-day international delivery options and rapid response support. Email Miya zheng WhatsApp |
| Q1 | Can AB7000-C connect an RS-485 device directly to PROFIBUS? Yes, when the serial electrical format and transaction behavior are correctly configured and the PROFIBUS I/O map matches the controller project. |
| Q2 | What must be preserved when replacing HMS AB7000-C? Keep the serial settings, transaction definitions, PROFIBUS address, I/O lengths and PLC byte mapping. |
| Q3 | Is ABC3000-A a drop-in replacement for AB7000-C? No automatic drop-in assumption should be made; recreate and validate the gateway project before commissioning. |
| Q4 | Which AB7000-C details should be photographed before removal? Capture rotary address settings, connector wiring, shield termination, power terminals and every configuration screen. |
| Q5 | How should AB7000-C be tested after installation? Verify power and status LEDs, serial polling without timeouts, PROFIBUS diagnostics and correct byte-level process values. |
| 6ES5941-7UB11 | 57C413B | 330130-045-00-CN | SD833 3BSC610066R1 | TK-HAO081 |
| 1783-US08T | IMASI13 | LV429386 | 6ES5304-3UB11 | AAI143-H53 S1 |
| SDCS-DSL-4 | 146031-01 | 51403776-100 | MPL-B230P-EJ44AA | ATA4D-00 S2 |
| IC630CHS308 | 3RP2525-1BW30 | 6DP1641-8AA | C100/0200/STD | 172103-01 |
| C7076A1015 | 80026-044-06 | EB501-50 S2 | DDNP1501 | BSU09H |
| SDCS-POW-1 | 3500/64M 176449-05 | 51402497-200 | 2097-V34PR5-LM | ADV551-P50 S2 |
| IC630CCM300 | H3DE-S1 | 6ES5756-0AA11 | 07KT92 GJR5250500R0262 | 136188-02 |
| 38500148-300 | 1785-BCM/C | 57C404B | GHQ6310062R0111 | LPU100H |
| 6SY8102-0LA03 | 330103-00-04-05-02-00 | A3C40173228 | 80190-100-01-R | T7412B1008 |
| TSXPSY2600 | SR2E201BD | XAGO12H | LG-003842 | 6ES5460-4UA11 |
| 01 Contact within 7 days Send the order details, photographs and a clear description of the concern. |
02 Preserve original condition Approved returns must retain original condition, packaging and supplied accessories. |
03 Inspection and resolution Return or replacement follows receipt and inspection; return shipping remains the buyer's responsibility. |
| Sales manager: Miya zheng | sales@amikon.cn | WhatsApp: 86-18020776792 |



Inventory Products


More than 40.000.000 products available and worldwide support