EMERSON / CONTROL TECHNIQUES
SM-APPLICATIONS
|
OverviewSpecificationsIntegrationRelated ModelsFAQ |
|
TASK RAIL
DPL
NET
|
PROGRAMMABLE DRIVE OPTION
SM-APPLICATIONSUnidrive SP Applications Solutions Module
A programmable Unidrive SP Solutions Module that adds a dedicated second processor for application-specific DPL programs, real-time sequencing, motion functions, drive-to-drive networking and auxiliary digital I/O. It is powered by the compatible host drive.
Sales manager: Miya zheng | sales@amikon.cn | WhatsApp: 86-18020776792
|
|
01
Host platform
Unidrive SP; compatibility must be confirmed for the installed drive and firmware
|
02
Module role
Programmable applications and motion-control second processor
|
03
Program technology
DPL application program
|
|
04
Flash memory
384 KB
|
05
User program memory
80 KB
|
06
High-speed network
CTNet, up to 5 Mbit/s
|
|
07
Serial interface
EIA-RS485
|
08
Serial protocols
ANSI; Modbus RTU master/slave; Modbus ASCII master/slave
|
09
Digital inputs
Two 24 V inputs
|
|
10
Digital outputs
Two 24 V outputs
|
11
Drive menus
15, 16 or 17 according to option slot
|
12
Programming relationship
SYPT project must target the correct drive and slot
|
| Unidrive SP Slot Defines menu 15, 16 or 17 and supplies the module. |
> | Second Processor Executes the machine-specific DPL application. |
> | CTNet / RS485 / I/O Links drives, serial devices and auxiliary signals. |
|
Q1
|
Can Emerson SM-APPLICATIONS be installed without the original DPL program?
The module can be fitted, but it cannot reproduce the machine-specific application until the correct DPL program and associated drive parameters are restored.
|
|
Q2
|
Is Emerson SM-APPLICATIONS interchangeable with SM-Applications Lite or Plus?
No automatic interchange should be assumed. Compare CTNet, RS485, digital I/O, motion functions, memory needs and the compiled project target.
|
|
Q3
|
Why does the option slot matter for Emerson SM-APPLICATIONS?
Unidrive SP maps the module to menu 15, 16 or 17 according to its slot. The SYPT project and inter-option links must preserve that relationship.
|
|
Q4
|
What should be backed up before replacing Emerson SM-APPLICATIONS?
Save the DPL project, compiled program, drive parameter set, menu 18 to 20 values, CTNet node settings, serial parameters and required RAM data.
|
|
Q5
|
What does Loading mean after fitting Emerson SM-APPLICATIONS?
During first installation the second processor can synchronize its parameter database with the host drive. Persistent loading or option trips must be resolved before motion is enabled.
|
|
Q6
|
How should Emerson SM-APPLICATIONS be tested after replacement?
Verify program auto-run, task scheduling, CTNet traffic, RS485 communication, digital I/O, trip handling, synchronized motion and all machine interlocks.
|
| ANT502-50 | 6SE7038-6GK84-1JC2 | 2071-A15 |
| PR6424/006-030 | IC695RMX128 | RLX2-IHNF-E |
| IC200PNS002-AB | ABC4013-A | A2SAT105-S000 |
| 2093-AC05-MP1 | FU20-05-T1-NPT | TXM1.8D |
| KJ4110X1-BA1 | PR6423/003-110 | PR9268/601-000 |
| X-CPU 01 985210211 | T6861H2WB-M | F3236 984323602 |
| NBG-12LX | MVME172-263 | 330180-51-00 |
| 80190-480-01-R | KL2001X1-BA1 | 9905-969 |
| MVME172 | Tricon 3006 | 3HAC029032-004 |
| 80190-478-51 | IC694ALG390C | ANT401-50 |
| IC694MDL645E | PLX51-HART-4I | KPS-600/20-ESC |
| 1109S | IC695CRU320 | A1BR4D-05 |
| C98043-A7105-L4-9 | PR6424/00A-110 | MVME167-034B |
| 1756-L73 | IC695CPE310 | 2094-AM05-S |
| AIP830-101 | ESC-PLATINE | Tricon 4329 |
| 80190-320-02-R | 00-128-456 | UT55A-001-11-00 |
Send the module label, host drive code and firmware, installed slot, DPL project status, CTNet arrangement, quantity and delivery target.
SEND YOUR REQUIREMENT


Inventory Products