The Emerson EPRO PR6423/014-040 CON021 is a paired eddy current measurement solution built around the PR6423 sensor and CON021 signal converter. The probe detects changes in the distance between its sensing face and a conductive target without physical contact. The converter supplies the sensor and conditions the resulting signal for connection to compatible machinery monitoring equipment.
This measurement principle is suitable for continuous monitoring of rotating equipment where shaft movement, vibration and relative position are important operating variables. The PR6423 series is designed for industrial machinery applications, including turbines, compressors, pumps and other rotating assets.
|
01 / PR6423 Probe
Detects the distance and movement of a conductive shaft surface through an electromagnetic field.
|
02 / CON021 Converter
Supplies and conditions the probe signal, delivering a voltage output for the monitoring channel.
|
| Sensor family | PR 6423 |
| Sensor head diameter | 8 mm |
| Nominal static measuring range | ±1.0 mm |
| Recommended dynamic range | 50–500 μm peak-to-peak |
| Sensitivity | 8 V/mm (42CrMo4 target material) |
| Nominal center-point distance | Approx. 1.5 mm |
| Basic air gap | Approx. 0.4–0.7 mm |
| Operating temperature | −35 to +180°C; short-term up to +200°C |
| Maximum vibration | 5 g at 60 Hz |
| Measuring target | Conductive target; standard calibration material 42CrMo4 / SAE 4140 |
| Series standard | PR6423 corresponds to API 670 / DIN 45670 |
| Converter model | CON021 |
| Compatible sensor families | PR6422, PR6423, PR6424, PR6425, PR6426 and PR6453 |
| Frequency range (−3 dB) | 0–20 kHz (with 10 nF capacitive load) |
| Rise time | Less than 15 μs (with 1 nF capacitive load) |
| Output voltage | −2 to −18 V factory setting; configurable −4 to −20 V |
| Supply voltage | −21 to −32 V for −2 to −18 V output; −23 to −32 V for −4 to −20 V output |
| Operating temperature | −30 to +100°C |
| Shock and vibration | 5 g at 60 Hz at 25°C |
| Protection class | IP20 |
| Transducer connection | Self-locking LEMO socket |
| Supply / output connection | Screw terminals, maximum 1.5 mm² wire |
| Housing material | LMgSi 0.5 F22 |
| Weight | Approx. 120 g |
| Mounting | Four M5 × 20 screws |
|
01
Target Detection
The PR6423 probe generates an electromagnetic field toward the conductive shaft surface.
|
› |
02
Signal Conversion
The CON021 converter supplies the probe and converts the sensor response into a voltage signal.
|
› |
03
Machine Monitoring
The output is connected to compatible monitoring electronics for condition evaluation.
|
The measurement chain can be used for static and dynamic distance measurements when paired with suitable evaluation electronics. The final measurement range and output behavior depend on the matched sensor, converter configuration, target material and installation conditions.
|
01 · Steam & Gas Turbines
Monitor shaft vibration, axial movement and relative position as part of a machinery protection arrangement.
|
02 · Compressors
Track shaft movement and vibration trends to support rotating equipment condition monitoring.
|
|
03 · Pumps & Fans
Provide non-contact displacement measurement for rotating shafts in industrial drive systems.
|
04 · Machinery Protection
Connect the conditioned output to compatible monitoring electronics for machinery status evaluation.
|
| 01 | Mounting position Use a stiff, vibration-free sensor holder with the correct mounting thread. Keep the sensing face aligned with the target surface. |
| 02 | Target material Confirm the target material and calibration condition. Standard PR6423 measuring-chain calibration is based on 42CrMo4 / SAE 4140 unless otherwise specified. |
| 03 | Probe gap adjustment Set the distance using the complete sensor-converter chain and check the converter output with suitable test equipment. |
| 04 | Cable routing Avoid twisting, sharp bending and mechanical strain. Keep cables and connectors clear of rotating components. |
| 05 | Electrical verification Check the CON021 supply range, output configuration, grounding, shielding and monitor input compatibility before operation. |
|
PRODUCT SUPPORT
Talk to AMIKON
Fast response for industrial spare parts
|
|
A
Non-contact sensing
Measures conductive target movement without mechanical contact between the probe and shaft.
|
B
Dynamic response
The CON021 converter supports a nominal frequency range up to 20 kHz under specified load conditions.
|
C
System compatibility
The CON021 is designed for compatible PR642x sensor families and related machinery measurement applications.
|
| Series | Nominal Static Range | Sensitivity |
| PR6422 | ±0.5 mm | 16 V/mm |
| PR6423 | ±1.0 mm | 8 V/mm |
| PR6424 | ±2.0 mm | 4 V/mm |
| PR6426 | ±4.0 mm | 2 V/mm |
|
NEED THIS PART?
Contact Our Team
|
|
AMIKON LIMITED
Keep Your Systems Moving.
Tell us the model and quantity you need.
|
| No. | Part Number | No. | Part Number |
| 01 | SICK LMS511-10100 | 26 | 3RU2116-1AB0 |
| 02 | Honeywell TC-FPCXX2 | 27 | VAV-SD2A |
| 03 | METSO IOP345 | 28 | 60-1281-01 |
| 04 | ABB DSPB120 57340001-T | 29 | KJ4001X1-CC1 |
| 05 | ABB DSPC155 57310001-CX | 30 | KJ4001X1-CB1 |
| 06 | ABB DSCS116 57520001-BZ | 31 | KJ3208X1-BK1 |
| 07 | Allen Bradley 150-F135NBDB | 32 | SB-DIM4c3A-DN |
| 08 | 330101-00-12-05-02-02 | 33 | 700-K40E-ZY |
| 09 | AX-DIM4-MI5 | 34 | 3TF3001-0XL2 |
| 10 | BZE6-2RN | 35 | LV429386 |
| 11 | GE CR2940U202 | 36 | 140XTS00100 |
| 12 | 7EX290.50-1 | 37 | KFD2-CRG2-1.D |
| 13 | X20AI2237 | 38 | WAGO 750-323 |
| 14 | 900-2RS | 39 | PW482-10 |
| 15 | LQSE-4S10-D | 40 | GHQ6310062R0111 |
| 16 | T6861H2WB-M | 41 | DDNP1501 |
| 17 | CL-317-61 | 42 | TSXPSY2600 |
| 18 | 6SE7041-2WL84-1JC1 | 43 | L5504AMP |
| 19 | 6SE7034-6EE85-1AA0 | 44 | 12GM35-N0 |
| 20 | 6SL3225-0BE37-5AA0 | 45 | 181B0331 |
| 21 | 6SL3100-1CE14-0AA0 | 46 | 6ES7195-7KF00-0XA0 |
| 22 | 6SE7032-7EB87-2DA0 | 47 | FU5200 |
| 23 | MYQ-SGC2WCH | 48 | PFD-402-N1 |
| 24 | PL-FD113S | 49 | BMXXBP0400 |
| 25 | EM-07E | 50 | MFM384-R-C |



Inventory Products


More than 40.000.000 products available and worldwide support