BENTLY NEVADA™ • SEISMOPROBE VELOCITY TRANSDUCER
9200-01-05-10-00Two-Wire Velocity Transducer for Machine Vibration Monitoring
The Bently Nevada 9200 Seismoprobe is a two-wire moving-coil velocity transducer designed to measure absolute bearing housing, casing and structural vibration. Its voltage output is directly proportional to vibration velocity, making it suitable for continuous monitoring and periodic measurement applications. 20 mV/mm/s 4.5–1000 Hz 2-Wire Design
|
PART NUMBER
9200-01-05-10-00
|
|
SENSITIVITY
20 mV/mm/s
500 mV/in/s, ±5%
|
FREQUENCY RESPONSE
4.5–1000 Hz
+0, -3 dB typical
|
TEMPERATURE
-29°C to +121°C
9200 operating & storage range
|
|
01
Mounting Angle
0° mounting orientation with a 4.5 Hz minimum operating frequency. |
05
Connector
Terminal block, top-mounted, with no integral cable. |
10
Mounting Base
Circular base with an M10X1 stud. |
00
Approval Option
No agency approval option selected for this configuration. |
|
01 / MACHINE MEASUREMENT
Bearing Housing & Casing VibrationThe 9200 is designed to measure absolute vibration of bearing housings, machine casings and structures. The moving-coil design produces an electrical output proportional to vibration velocity. |
02 / CONDITION MONITORING
Continuous or Periodic MeasurementThe two-wire 9200 can be used for continuous monitoring or periodic measurements together with appropriate monitoring, test or diagnostic equipment. |
|
03 / MAINTENANCE SIGNAL
Vibration Changes as an Early ClueCommon machine problems such as unbalance and misalignment can appear as an increase or change in rotor vibration. Effective casing measurement depends on transmitting sufficient rotor vibration to the mounting location. |
04 / INSTALLATION QUALITY
Mounting MattersCorrect installation on the bearing housing or casing is important. Poor installation can reduce amplitude and frequency response or create signals that do not represent actual machine vibration. |
|
SUPPLY SUPPORT
Prepared for Maintenance Timing
|
WHEN DOWNTIME MATTERS
A Practical Replacement ChoiceWhen a vibration channel becomes unavailable, unstable or difficult to validate, restoring the correct transducer configuration can be important to maintaining reliable machine-condition measurements. The 9200 is designed for vibration measurement where casing, bearing housing or structural response needs to be monitored. For a quotation, please provide:
Part Number · Quantity · Destination · Required Date · Machine/System
|
|
Professional customer support for industrial automation requirements
|
Efficient inventory support for automation spare-part requirements
|
|
GLOBAL AUTOMATION SUPPORT
More Parts. Faster Response. Practical Support.
20+ language services · Customers in 149 countries and regions · UK & US distribution centers Our sales office responds actively to spare-part inquiries and works with customers to identify practical replacement options and delivery arrangements. We support electrical and industrial automation control spare parts and can also discuss stocking requirements beyond standard product ranges. |
| 01. What does the 9200-01-05-10-00 measure?
It measures absolute vibration relative to free space at bearing housings, machine casings and structural mounting locations. |
02. What type of transducer technology does this configuration use?
The 9200 uses a two-wire moving-coil design and generates a voltage output directly proportional to vibration velocity. |
| 03. What is the sensitivity of the 9200?
The nominal sensitivity is 20 mV/mm/s, equivalent to 500 mV/in/s, with ±5% specified when properly terminated and oriented at the calibration angle. |
04. What makes the 9200-01-05-10-00 configuration distinctive?
The code specifies a 0° mounting orientation with a 4.5 Hz minimum operating frequency, terminal-block top mount, circular M10X1 mounting base and no agency approval option. |
| 05. Where can the 9200 be used in a vibration monitoring arrangement?
It can be used for continuous monitoring or periodic measurements of bearing housing, casing and structural vibration with appropriate monitoring, test or diagnostic equipment. |
06. What should be considered when replacing this transducer?
Confirm the complete part-number configuration, mounting arrangement, cable or terminal connection, operating environment and the requirements of the connected monitoring system before replacement. |
|
ABB
3HAC055697-004
3HAC055700-003 3HAC13398-2 3HAC17342-1 IMCOM03 SPDSI22 IMASO11 P-HC-BRC-30000000 BRC400 NTAI05 |
Allen-Bradley
1734-OE2V
1734-IR2 1734-OE4C 1734-IE2C 1734-ARM 1734-VHSC24 1769-L36ERM 5069-L310ER 1756-EN2T 1734-AENTR |
Others
UD326
PS-12-0 EL105C EP-4201-Z2 / OPC-VG7-TL SLVA-4K 426.0013 - 1125 SGMAH-04ABA41 DI40EX RES 392887 EFCB72T-JC1 |
|
READY TO CHECK AVAILABILITY?
Let's Get Your 9200-01-05-10-00 Requirement Moving.Please send the Part Number, Quantity, Destination, Required Date and Machine/System so we can respond with a practical quotation. |



Inventory Products


More than 40.000.000 products available and worldwide support