◆ BENTLY NEVADA / 3300 XL 11 mm
330730-080-10-05
8 m FluidLoc extension cable
A 75 ohm coaxial extension cable for completing a 9 m 3300 XL 11 mm proximity measurement chain when paired with a 1 m probe and a 9 m Proximitor Sensor.
|
![]() |
| 080 8.0 m cable length |
10 FluidLoc cable, without armor or protector |
05 Multiple approvals |
|
02 / SYSTEM LENGTH
Build the electrical chain to 9 m
The probe lead plus this extension cable must equal the selected Proximitor Sensor length. |
1 m 11 mm probe lead |
+ | 8 m 330730-080-10-05 |
= | 9 m matched system |
| ◆ Sales manager: Miya zheng | ✉ sales@amikon.cn | ☎ 86-18020776792 |
| Cable construction | 75 ohm FEP-insulated coaxial FluidLoc cable | Typical capacitance | 69.9 pF/m |
| 8 m core resistance | 2.0 +/- 0.5 ohm | 8 m outer conductor | 0.6 +/- 0.2 ohm |
| Temperature range | -52 to +177 C | Minimum bend radius | 25.4 mm |
FluidLoc advantage: reduces the possibility of oil or other liquid travelling through the cable interior. It does not replace external routing protection.
|
04 / AMIKON LIMITED
Listen. Think. Solve.
Industrial automation support spanning PLC, DCS, machinery protection, drives and robot components across active and legacy platforms. Multilingual support | International delivery | Order tracking
|
| Q1 | Can 330730-080-10-05 be used with a 5 m Proximitor Sensor? | No. An 8 m extension plus a 1 m probe forms a 9 m chain and requires the matching 9 m sensor. |
| Q2 | Does 330730-080-10-05 include connector protectors? | No. Code 10 specifies FluidLoc cable without a protector; environmental protection must be selected separately where needed. |
| Q3 | Can 330730-080-10-05 be substituted with a standard 8 m coaxial cable? | No. Use the specified 75 ohm 3300 XL cable construction and ClickLoc interfaces to preserve system performance. |
| Q4 | What must be recorded before ordering 330730-080-10-05? | Confirm probe lead length, Proximitor Sensor length, FluidLoc requirement, connector condition and approval scope. |
| Q5 | What should be inspected when 330730-080-10-05 arrives? | Check both connectors, ferrules, cable jacket, length marking, continuity and signs of tight bending or crushing. |
| AFP2441 | 6ES7952-1AP00-0AA0 | 1771-OB | 1771-OZL | 1771-IB |
| 1771-OW | AB7000-C | IMASI13 | 1771-ASB/E | WDP5-118.051-00 |
| SOIA-01 | 6AU1425-2AD00-0AA0 | AINT-02C | 8102-HO-IP | 1771-OA |
| ATV32HU75N4 | AC48545001-C | T8451C | 140ACI03000C | 140CPS12420C |
| 140XCP50000 | TSXLES65 | TSXP4720 | TSXP57153M | MVI56-101M |
| 4303-MNET-MBP | AN-X2-AB-DHRIO | H4135A | F3421 | F6205 |
| 01984-4080-0001 | 01984-4282-0001 | 6SE7090-0XX84-0AF0 | 6SX7010-0FJ00 | 6SL3055-0AA00-3KA0 |
| CBH215CH506 | 6SL3000-0KH14-0AA0 | KC4011X1-BD1 | KJ3242X1-BA2 | RM100-EM-8SFP |
| PR6423/005-110 | PR6426/000-030 | PR9268/202-100 | 6ES5928-3UB12 | FTA-T-01 |
| ACS880-01-156A-5 | MQDB045D1A04 | DSDX452 2716075-P | DSAX452 5712289-A | 330104-00-13-15-01-00 |
| Contact within 7 days Send order details, clear photographs and a concise description. |
Preserve original condition Approved returns must retain packaging and supplied accessories. |
Inspection and resolution Return or replacement follows receipt and inspection; return freight remains the buyer's responsibility. |



Inventory Products


More than 40.000.000 products available and worldwide support