Honeywell DCS System

BENTLY NEVADA

Home Brands BENTLY NEVADA

Bently Nevada 330704-00-50-10-01-05 11 mm Proximity Probe

Bently Nevada 330704-00-50-10-01-05 11 mm Proximity Probe

Product Type

3300 XL 11 mm Proximity Probes

Origin

Made in U.S.A

Certificate Of Origin (COO)

Available as add-on

Overall Case Length Option (050)

50 mm

Total Length Option (10)

1.0 metre (3.3 feet)

3300 XL / 11 mm METRIC SYSTEM
330704-00-50-10-01-05
M14 x 1.5 armored probe with protected connector

An 11 mm eddy-current proximity probe built for an extended 4.0 mm linear range. The 1.0 m lead is combined with a suitable extension cable and a 3300 XL 11 mm Proximitor Sensor.

 
 
01 / ORDER-CODE MAP
330704 11 mm / M14 x 1.5 / armor
00 / 50 0 mm unthreaded / 50 mm case
10 / 01 1.0 m standard cable / ClickLoc connector protector
05 multiple approvals
02 / PERFORMANCE WINDOW
Designed for greater measurement range
4.0 mm
linear range
3.94 V/mm
scale factor
0-8 kHz
response
2.5 mm
recommended gap
Recommended flat target 30.5 mm minimum Recommended shaft 152 mm minimum
Probe temperature -52 to +177 C M14 engagement limit 21 mm
03 / SYSTEM COMPLETION
Select the extension cable by total system length
5 m system

1 m probe + 4 m extension cable + 5 m 3300 XL 11 mm Proximitor Sensor.

9 m system

1 m probe + 8 m extension cable + 9 m 3300 XL 11 mm Proximitor Sensor.

Do not mix families

Keep the probe, extension cable and Proximitor Sensor within the 11 mm system.

 
04 / AMIKON LIMITED
Global reach. Practical expertise.

Automation components for PLC, DCS, safety, turbine, robotics and machinery-monitoring platforms.

Listen: understand the installed system and urgency.

Think: match the exact code, interface and operating need.

Solve: coordinate difficult-to-find components through a cross-continental network.

05 / BUYER FAQ
Checks that protect 11 mm system compatibility
Q1 What mounting geometry must match Bently Nevada 330704-00-50-10-01-05?
Confirm M14 x 1.5 thread, 0 mm unthreaded length, 50 mm case length, 1.0 m probe lead and a maximum thread engagement of 21 mm.
Q2 Which extension cable completes Bently Nevada 330704-00-50-10-01-05?
Pair its 1.0 m probe lead with a 4.0 m or 8.0 m 3300 XL 11 mm extension cable to create a 5 m or 9 m system.
Q3 Why should Bently Nevada 330704-00-50-10-01-05 not be paired with an 8 mm Proximitor Sensor?
The 11 mm system uses a 3.94 V/mm scale factor and 4.0 mm linear range. Its probe, extension cable and 11 mm Proximitor Sensor must remain within the same system family.
Q4 What target geometry matters for Bently Nevada 330704-00-50-10-01-05?
Use a conductive target with a recommended flat diameter of at least 30.5 mm; the recommended minimum shaft diameter is 152 mm.
Q5 What should be inspected on Bently Nevada 330704-00-50-10-01-05 before installation?
Inspect the 11 mm PPS tip, M14 threads, armor, cable transition, ClickLoc connector and protector, then confirm a 25.4 mm minimum bend radius.
06 / MORE COMPONENTS
Recommended industrial automation models
VT-VSPA1-1-11 H4135A 149992-02 8108-4003 4000103-520
2711-B5A1 LXM15MD28N4 1756-L83E T9802 900H03-0102
MVI56-MDA4 330750-20-05 7379A31G04 330192-00-25-10-00 F8621A
135137-01 LPU100H 4000098-510 1394C-SJT10-T-RL ATV61HD37N4
1746-P5 T8110B UVL682 MVI56-GSC 100630-00-60-05-01
F6215 CI615 3BHT300024R1 8261-4154 125840-02 BSU09H
4000093-310 1394-AM07 AS-S908-110 51403299-200 T3420A
UVC752 3A99132G02 VT3002-2X/32D F3421 INFI90 INFI 90
8152-4002 DSCA120 57520001-P XAGO12H ME4U07AAA 80026-044-06-R
AM-SA85-000 NTDI21-A 3100-INUSA 21500-00-28-10-02 5X00594G01
07 / AFTER-DELIVERY CARE
CONTACT

Reach us within seven days with order details and photographs.

CONDITION

Keep the item, packaging and accessories in original condition.

OUTCOME

A return or replacement is arranged after receipt and inspection; buyer covers return shipping.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Bently Nevada 3500/22M 138607-01 Transient Data Interface Module
Bently Nevada 3500/22M 138607-01 Transient Data Interface Module

The 3500/22M 138607-01 Transient Data Interface (TDI)   is the interface between the 3500 monitoring system and   compatible software (System 1 Condition Monitoring   and Diagnostic software and 3500 System Configuration   software). The TDI combines the function of a 3500/20   Rack Interface Module (RIM) with the data collection   capability of a communication processor such as TDXnet.

Bently Nevada 3500/22M 288055-01 Transient Data Interface
Bently Nevada 3500/22M 288055-01 Transient Data Interface

3500/22M is a Transient Data Interface Module manufactured and designed by Bently Nevada as part of the 3500 Series used for monitoring seismic activity. The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet.

Bently Nevada 3500/33 149986-01 16-Channel Relay Module
Bently Nevada 3500/33 149986-01 16-Channel Relay Module

The 3500/33 16-Channel Relay Module is a full-height module   that provides 16 relay outputs. You can place any number of   16-channel relay modules in any of the slots to the right of the   Transient Data Interface (TDI) Module.   Each output of the 3500/33 16-Channel Relay Module can be   independently programmed to perform voting logic.

Bently Nevada 3500/60 163179-01 Temperature Monitor Module
Bently Nevada 3500/60 163179-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The modules condition these inputs and   compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/60 133811-01 Temperature Monitor Module
Bently Nevada 3500/60 133811-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The 3500/60 133811-01 modules condition   these inputs and compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor
Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor

The 3500/72M Recip Rod Position Monitor meets API 618   requirements for reciprocating compressors. It measures:   l Rod position   l Rod drop   l Hyper-compressor   The four-channel 3500/72M Recip Rod Position Monitor   accepts input from proximity transducers, conditions the   signal to provide dynamic and static position measurements,   and compares the conditioned signals with userprogrammable alarms.   Each channel, depending on how you configure it, typically   conditions its input signal to generate various parameters   called measured values.

Bently Nevada 3500/62 163179-03 Process Variable Monitor
Bently Nevada 3500/62 163179-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Bently Nevada 3500/62 133811-03 Process Variable Monitor
Bently Nevada 3500/62 133811-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact