Bently Nevada 330180-X1-CN MOD:143416-05 3300 XL 8 mm Proximitor Sensor

Bently Nevada 330180-X1-CN MOD:143416-05 3300 XL 8 mm Proximitor Sensor

 
 
MACHINE MONITORING
330180
X1-CN / MOD 143416-05
3300 XL PROXIMITOR
8 mm SYSTEM
PROXIMITY MONITORING
DIN RAIL MOUNTING
 
SENSOR PERFORMANCE PANEL
SUPPLY −17.5 to −26 V DC
OUTPUT 50 Ω output resistance
INPUT Compatible 3300 5 mm / XL 8 mm probe and extension cable
DIN-rail mounting design. Electrical isolation is incorporated into the base for the applicable X1-CN configuration.
 
Miya Zheng
Sales Manager
3300 XL 8 mm PROXIMITY SYSTEM

330180-X1-CN

MOD:143416-05

A modified 3300 XL 8 mm Proximitor Sensor that conditions the probe signal for non-contact shaft vibration and position measurement. The complete X1, CN and MOD markings must remain together during replacement selection.

2.0 mm
Linear range
7.87 V/mm
Nominal scale factor
0-10 kHz
Frequency response
Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
01 / SYSTEM CHAIN

Three matched components form one measurement system

8 mm PROBE
Detects shaft-to-tip gap
➞ EXTENSION CABLE
Completes total electrical length
➞ 330180-X1-CN
Conditions the signal
Compatibility rule: probe length plus extension-cable length must equal the total system length required by the Proximitor Sensor configuration.
02 / PERFORMANCE PROFILE

Values that define the 3300 XL 8 mm system

Product role Modified 3300 XL 8 mm Proximitor Sensor
Measurement principle Eddy-current non-contact displacement measurement
Linear range 2.0 mm / 80 mil
Scale factor 7.87 V/mm / 200 mV/mil nominal
Frequency response 0 to 10 kHz, typical system response
Reference target AISI 4140 steel for stated system performance
Configuration control X1, CN and MOD:143416-05 must be checked as one complete marking
03 / ORDER-CODE DECISION

Standard family versus modified configuration

Configuration What it controls Buyer action
330180-X1-CN
MOD:143416-05
Modified total-length, mounting or regional configuration controlled by the full marking Match every character and the MOD number; do not translate X1 into a standard code.
330180-50-00 Standard 5.0 m system length, panel mount, approvals not required Use only when this exact standard mounting and length are required.
330180-51-05 Standard 5.0 m system length, DIN mount, multiple approvals Use for the stated standard DIN arrangement, not as an assumed MOD substitute.
Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
AMIKON LIMITED

Automation parts support across continents

We coordinate PLC, DCS, HMI, drive, industrial computer and machinery-monitoring components for industrial users worldwide.

Broad capability. Support covers ABB, Honeywell, Rockwell Automation, ICS Triplex, Triconex, GE, Yokogawa, Bently Nevada, Emerson and other established platforms.

Responsive service. A multilingual team supports part review, order tracking and international delivery.

PURCHASE FAQ

Questions that protect a modified transducer order

Q1 What label evidence is required before ordering Bently Nevada 330180-X1-CN MOD:143416-05? Capture one readable image showing 330180-X1-CN and MOD:143416-05 together, plus mounting style, terminal side and installed probe/cable markings. A quotation based only on 330180 can miss the controlled modification.
Q2 How should the system length be confirmed for Bently Nevada 330180-X1-CN MOD:143416-05? Record the probe integral-lead length and extension-cable length, then confirm their sum matches the installed Proximitor configuration. Do not infer X1 from a standard 10, 50 or 90 option.
Q3 Can a standard 330180 be calibrated to replace Bently Nevada 330180-X1-CN MOD:143416-05? Standard 3300 XL components are interchangeable within the correct system length, but a modified sensor must first be matched to its controlled mounting, regional marking and MOD requirements. Calibration does not correct a wrong hardware configuration.
Q4 Which electrical readings help verify Bently Nevada 330180-X1-CN MOD:143416-05 before service? Check supply voltage and polarity, common and output wiring, probe gap voltage, monitor input type and scale factor. An abnormal gap voltage may indicate wrong system length, damaged cabling, target geometry or an installation gap error.
Q5 What arrival inspection matters most for Bently Nevada 330180-X1-CN MOD:143416-05? Verify the complete label and MOD marking first. Then inspect the coaxial connection, terminal block, mounting base, enclosure and isolation surfaces for impact, corrosion, heat damage or unauthorized repair.
AVAILABLE MODELS

Recommended automation parts

1771-P6S/B CC-TUIO41 TP830 3BSE018114R1 AI815 3BSE052604R1 FU20-05-T1-NPT
UT55A-001-11-00 CP471-01 IS220PSCAH1B 330180-51-00 DS822.OD110
PR-MAX-PRO AMPS-24E XP10-M DNC-T2032-A10 CP451-10
330101-00-63-10-02-00 DC-TDOD61 DC-PDIL51 DC-TDIL61 DC-TAOX11
DC-TAIX11 ICS Triplex T9902 ICS Triplex T9901 IC200CHS022L 80026-088-01-R
BA21504-00-08-10-02 21000-28-05-00-75-01-02 330180-X1-05 MOD:145004-90 330102-00-12-90-02-05 330101-00-36-05-02-05
38B6041X082 330704-000-100-10-01-RU 330103-00-07-10-02-05 086444-001 MPRC086444-001 CI526V1 3BSE012870R1
AH385851U003 AINT-02C 8102-HO-IP 1771-OA AB7000-C
IMASI13 1771-ASB/E WDP5-118.051-00 SOIA-01 6AU1425-2AD00-0AA0
1747-L542 XC5010C 1746-P1 1771-OB 1771-OZL
AFTER-DELIVERY SUPPORT

A clear three-stage resolution path

01 / Contact within 7 days
Send order details, photographs and a clear description.
  02 / Preserve original condition
Keep approved returns complete with packaging and accessories.
  03 / Inspection and resolution
Return or replacement follows receipt and inspection; return shipping remains the buyer's responsibility.
Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Bently Nevada 3500/22M 138607-01 Transient Data Interface Module
Bently Nevada 3500/22M 138607-01 Transient Data Interface Module

The 3500/22M 138607-01 Transient Data Interface (TDI)   is the interface between the 3500 monitoring system and   compatible software (System 1 Condition Monitoring   and Diagnostic software and 3500 System Configuration   software). The TDI combines the function of a 3500/20   Rack Interface Module (RIM) with the data collection   capability of a communication processor such as TDXnet.

Bently Nevada 3500/22M 288055-01 Transient Data Interface
Bently Nevada 3500/22M 288055-01 Transient Data Interface

3500/22M is a Transient Data Interface Module manufactured and designed by Bently Nevada as part of the 3500 Series used for monitoring seismic activity. The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet.

Bently Nevada 3500/33 149986-01 16-Channel Relay Module
Bently Nevada 3500/33 149986-01 16-Channel Relay Module

The 3500/33 16-Channel Relay Module is a full-height module   that provides 16 relay outputs. You can place any number of   16-channel relay modules in any of the slots to the right of the   Transient Data Interface (TDI) Module.   Each output of the 3500/33 16-Channel Relay Module can be   independently programmed to perform voting logic.

Bently Nevada 3500/60 163179-01 Temperature Monitor Module
Bently Nevada 3500/60 163179-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The modules condition these inputs and   compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/60 133811-01 Temperature Monitor Module
Bently Nevada 3500/60 133811-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The 3500/60 133811-01 modules condition   these inputs and compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor
Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor

The 3500/72M Recip Rod Position Monitor meets API 618   requirements for reciprocating compressors. It measures:   l Rod position   l Rod drop   l Hyper-compressor   The four-channel 3500/72M Recip Rod Position Monitor   accepts input from proximity transducers, conditions the   signal to provide dynamic and static position measurements,   and compares the conditioned signals with userprogrammable alarms.   Each channel, depending on how you configure it, typically   conditions its input signal to generate various parameters   called measured values.

Bently Nevada 3500/62 163179-03 Process Variable Monitor
Bently Nevada 3500/62 163179-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Bently Nevada 3500/62 133811-03 Process Variable Monitor
Bently Nevada 3500/62 133811-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 