Honeywell DCS System

BENTLY NEVADA

Home Brands BENTLY NEVADA

Bently Nevada 21000-34-05-15-029-04-02 Probe Housing Assembly

Bently Nevada 21000-34-05-15-029-04-02 Probe Housing Assembly

PROBE HOUSING
21000-34-05-15-029-04-02
External 3300 XL 8 mm proximity-probe housing assembly.
Contact QR code
ASSEMBLY GEOMETRY
0.5 m
Probe cable
1.5 in
Standoff
2.9 in
Penetration
✈ International Delivery on the Day
⚡ Quick Response Support
◆ Intercontinental Cooperation Network
 
 
 
 
REQUEST A MATCH
Sales manager
Miya zheng
✉ EMAIL MIYA ☎ WHATSAPP
BENTLY NEVADA / INDUSTRIAL AUTOMATION OVERVIEWSPECIFICATIONSSELECTIONFAQ
◎ EXTERNAL PROXIMITY PROBE HOUSING
21000-34-05-15-029-04-02
3300 XL 8 mm Probe Housing Assembly
 
A complete externally mounted assembly combining the specified probe, protected connector, cable length, standoff, penetration, conduit fitting and machine-case thread.
8 mm XL
PROBE
0.5 m
CABLE
1.5 in
STANDOFF
2.9 in
PENETRATION
◉ Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
▦ OPEN ASSEMBLY BOOK / 21000 SERIES
PROBE & REACH
34 Probe package
3300 XL 8 mm probe with connector protector and selectable approvals
05 Probe cable
0.5 m cable length
15 Standoff adapter
1.5 in nominal length
These three fields establish the sensing package and the fixed stand-off geometry.
PENETRATION & MOUNTING
029 Probe penetration
2.9 in nominal reach
04 Conduit fitting
One 3/4-14 NPT plug
02 Mounting interface
3/4-14 NPT machine-case thread
These fields establish target reach, conduit entry and the machine-case mounting interface.
Order rule: approve replacement only when all six suffix blocks match the installed dimensional and approval requirements.
Where This Assembly Fits
21000-34... 21000-33... 21000-36...
8 mm probe, protector and selectable approvals.

Use when: the installed assembly carries option 34.
8 mm probe and protector without the same approval selection.

Use when: the installed approval code supports it.
11 mm probe with protector and selectable approvals.

Use when: the monitored system is designed around an 11 mm probe.
 
◉ GLOBAL SUPPORT TEAM
WHY CHOOSE AMIKON?
Precise part-number handling for critical machinery components.
✓ Complete-code checks - suffixes, dimensions and supplied scope are reviewed before dispatch.
→ Legacy-system continuity - hard-to-find components help established monitoring systems remain operational.
◆ Responsive coordination - urgent maintenance requirements receive prompt sales attention.
12-month warranty. Raise concerns within seven days of receipt. Returned goods must remain in original condition with the reason stated. Return freight is arranged by the buyer.
◉ Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
Five Purchase Checks for 21000-34-05-15-029-04-02
01 Can 21000-34-05-15-029-04-02 be replaced by another 21000 code? Only after every option block matches the installed mechanical and approval requirements.
02 Does 21000-34-05-15-029-04-02 include the probe? Yes. Option 34 specifies a 3300 XL 8 mm probe with connector protector and selectable approvals.
03 What machine-case thread does 21000-34-05-15-029-04-02 use? The final 02 option specifies a 3/4-14 NPT mounting thread.
04 Why does the 2.9 in penetration of 21000-34-05-15-029-04-02 matter? It determines probe reach and target position; an incorrect length can prevent correct gap setup.
05 What should be measured before ordering 21000-34-05-15-029-04-02? Confirm standoff, penetration, conduit route, mounting thread, target location and hazardous-area approval need.
Send the complete 21000 code and installed dimensions.
GET A QUOTE →
◉ Sales manager: Miya zheng ✉ sales@amikon.cn ☎ 86-18020776792
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Bently Nevada 3500/22M 138607-01 Transient Data Interface Module
Bently Nevada 3500/22M 138607-01 Transient Data Interface Module

The 3500/22M 138607-01 Transient Data Interface (TDI)   is the interface between the 3500 monitoring system and   compatible software (System 1 Condition Monitoring   and Diagnostic software and 3500 System Configuration   software). The TDI combines the function of a 3500/20   Rack Interface Module (RIM) with the data collection   capability of a communication processor such as TDXnet.

Bently Nevada 3500/22M 288055-01 Transient Data Interface
Bently Nevada 3500/22M 288055-01 Transient Data Interface

3500/22M is a Transient Data Interface Module manufactured and designed by Bently Nevada as part of the 3500 Series used for monitoring seismic activity. The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet.

Bently Nevada 3500/33 149986-01 16-Channel Relay Module
Bently Nevada 3500/33 149986-01 16-Channel Relay Module

The 3500/33 16-Channel Relay Module is a full-height module   that provides 16 relay outputs. You can place any number of   16-channel relay modules in any of the slots to the right of the   Transient Data Interface (TDI) Module.   Each output of the 3500/33 16-Channel Relay Module can be   independently programmed to perform voting logic.

Bently Nevada 3500/60 163179-01 Temperature Monitor Module
Bently Nevada 3500/60 163179-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The modules condition these inputs and   compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/60 133811-01 Temperature Monitor Module
Bently Nevada 3500/60 133811-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The 3500/60 133811-01 modules condition   these inputs and compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor
Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor

The 3500/72M Recip Rod Position Monitor meets API 618   requirements for reciprocating compressors. It measures:   l Rod position   l Rod drop   l Hyper-compressor   The four-channel 3500/72M Recip Rod Position Monitor   accepts input from proximity transducers, conditions the   signal to provide dynamic and static position measurements,   and compares the conditioned signals with userprogrammable alarms.   Each channel, depending on how you configure it, typically   conditions its input signal to generate various parameters   called measured values.

Bently Nevada 3500/62 163179-03 Process Variable Monitor
Bently Nevada 3500/62 163179-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Bently Nevada 3500/62 133811-03 Process Variable Monitor
Bently Nevada 3500/62 133811-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact