Honeywell DCS System

BENTLY NEVADA

Home Brands BENTLY NEVADA

Bently Nevada 1900/65A 167699-02 172323-01 General Purpose Equipment Monitor

Bently Nevada 1900/65A 167699-02 172323-01 General Purpose Equipment Monitor

BENTLY NEVADA · MACHINE SIGNAL DESKIN STOCK
SIGNAL RECORD
MULTI-CHANNEL ASSET PROTECTION

1900/65A 167699-02 172323-01

General Purpose Equipment Monitor

Eight-channel monitor for continuous vibration and temperature supervision on essential and balance-of-plant machinery.

INPUTS4 dynamic + 4 temperatureOUTPUTS6 relays + 4 recorderNETWORKModbus connectivity
ORDER SUPPORT

Build the right request, first time.

Miya Zheng can check the complete code, availability and delivery window.

✉ sales@amikon.cnSTART AN ENQUIRY →
01 / EQUIPMENT DOSSIER

1900/65A 167699-02 172323-01

 

General Purpose Equipment Monitor

011900/65A platform
02167699-02 monitor assembly
03172323-01 associated configuration
SIGNAL ROUTE

From installed hardware to actionable condition data

STEP 1Collect vibration and temperature signals
STEP 2Evaluate configured alarm levels
STEP 3Pass status to local and plant systems

Eight-channel monitor for continuous vibration and temperature supervision on essential and balance-of-plant machinery.

CONFIGURATION SNAPSHOT

What the code defines

Dynamic inputs4 configurable channels
Temperature inputs4 thermocouple or RTD channels
Relay outputs6 configurable relays
Recorder outputsFour 4–20 mA loops
Typical assetsPumps, fans, blowers, motors, compressors
IntegrationStandalone operation or plant-system connection
INSTALLATION PATH

Three checks before energizing

1Confirm the power-input version and channel configuration.
2Record sensor types, scaling and alarm setpoints before changeout.
3Verify relay logic and communication mapping during commissioning.
SERVICE LIFE

Built for continuous protection of general-purpose machinery. Preserve the configuration backup, terminal plan and alarm philosophy so a future replacement can be commissioned with less downtime.

02 / FIELD FAQ

Five practical checks

 
01What does the 1900/65A monitor?
It accepts four dynamic vibration channels and four temperature channels for continuous equipment supervision.
02Can it work without a local display?
Yes. The monitor can operate independently; a display can be used when local indication is required.
03Which machines are typical candidates?
Common applications include pumps, fans, blowers, motors, cooling-tower drives and small compressors.
04What must be checked before replacement?
Confirm the power version, installed input sensors, channel scaling, relay logic and communication settings.
05What should be sent with an enquiry?
Send clear label photos, both listed part numbers, required quantity and destination.
03 / INVENTORY PATHS

More routes for maintenance teams

Published Siemens and ABB items open in a new window. The Others list is drawn from the supplied inventory set.

Others10 MODELS
01593CM-BOV16
02810-E440582/2
03CB273 42185-800-01
04BF100F 65A974G01
059125DAV
061955565-E
076EC1660-3A
08CLV440-0010
09809-112
10MSQB30R MHZL2-25D
04 / AMIKON NETWORK

When a machine stops, the search should not.

AMIKON connects maintenance teams with hard-to-find automation inventory, practical code matching and coordinated international delivery for planned outages and urgent recovery work.

1M+industrial parts
15 yearssourcing experience
OEM · MRO · SYSTEM INTEGRATOR SUPPORT
05 / READY FOR CODE MATCHING

Move from part-number uncertainty to a clear buying path.

Share the complete 1900/65A 167699-02 172323-01 code and delivery destination. Miya Zheng will help check availability and quotation details.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Bently Nevada 3500/22M 138607-01 Transient Data Interface Module
Bently Nevada 3500/22M 138607-01 Transient Data Interface Module

The 3500/22M 138607-01 Transient Data Interface (TDI)   is the interface between the 3500 monitoring system and   compatible software (System 1 Condition Monitoring   and Diagnostic software and 3500 System Configuration   software). The TDI combines the function of a 3500/20   Rack Interface Module (RIM) with the data collection   capability of a communication processor such as TDXnet.

Bently Nevada 3500/22M 288055-01 Transient Data Interface
Bently Nevada 3500/22M 288055-01 Transient Data Interface

3500/22M is a Transient Data Interface Module manufactured and designed by Bently Nevada as part of the 3500 Series used for monitoring seismic activity. The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet.

Bently Nevada 3500/33 149986-01 16-Channel Relay Module
Bently Nevada 3500/33 149986-01 16-Channel Relay Module

The 3500/33 16-Channel Relay Module is a full-height module   that provides 16 relay outputs. You can place any number of   16-channel relay modules in any of the slots to the right of the   Transient Data Interface (TDI) Module.   Each output of the 3500/33 16-Channel Relay Module can be   independently programmed to perform voting logic.

Bently Nevada 3500/60 163179-01 Temperature Monitor Module
Bently Nevada 3500/60 163179-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The modules condition these inputs and   compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/60 133811-01 Temperature Monitor Module
Bently Nevada 3500/60 133811-01 Temperature Monitor Module

The 3500/60 & 61 modules provide six channels of   temperature monitoring and accept both Resistance   Temperature Detector (RTD) and Thermocouple (TC)   temperature inputs.  The 3500/60 133811-01 modules condition   these inputs and compare them against user-programmable alarm setpoints.    The 3500/60 and 3500/61 provide identical functionality   except that the 3500/61 provides recorder outputs for each of   its six channels while the 3500/60 does not.

Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor
Bently Nevada 3500/72M 176449-08 Recip Rod Position Monitor

The 3500/72M Recip Rod Position Monitor meets API 618   requirements for reciprocating compressors. It measures:   l Rod position   l Rod drop   l Hyper-compressor   The four-channel 3500/72M Recip Rod Position Monitor   accepts input from proximity transducers, conditions the   signal to provide dynamic and static position measurements,   and compares the conditioned signals with userprogrammable alarms.   Each channel, depending on how you configure it, typically   conditions its input signal to generate various parameters   called measured values.

Bently Nevada 3500/62 163179-03 Process Variable Monitor
Bently Nevada 3500/62 163179-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Bently Nevada 3500/62 133811-03 Process Variable Monitor
Bently Nevada 3500/62 133811-03 Process Variable Monitor

The 3500/62 Process Variable Monitor is a 6-channel monitor   for processing machine critical parameters that merit   continuous monitoring, such as pressures, flows,   temperatures, and levels. The monitor accepts +4 to +20 mA   current inputs or any proportional voltage inputs between -10   Vdc and +10 Vdc. It conditions these signals and compares   the conditioned signals to user-programmable alarm   setpoints. 

Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact