ALLEN-BRADLEY 1771 I/O
1771-OAEight-Point 120 V AC Output ModuleA discrete output module for a 1771 I/O chassis, with individual point status and blown-fuse indication for service visibility. |
![]() |
| 8 OUTPUTS | 92-138 V AC | 6 A MAXIMUM |
| Sales manager Miya zheng |
Email sales@amikon.cn | WhatsApp 86-18020776792 |
| 01 |
ELECTRICAL RATING SHEET
Load limits and chassis requirements |
| Outputs | 8 |
| Voltage | 92-138 V AC, 47-63 Hz |
| Current | 1.5 A per point; 6 A module maximum |
| Surge | 4 A for 8.3 ms, repeatable every second |
| Minimum load | 50 mA at 120 V AC, 60 Hz |
| On-state drop | 2 V at 100 mA |
| Off-state leakage | 5 mA maximum |
| Delay | 1.0 ms on; 8.3 ms off at 60 Hz |
| Backplane | 210 mA at 5 V DC +/-5% |
| Dissipation | 10.7 W maximum |
| Wiring arm | 1771-WA |
| Keying | 4-6 and 12-14 |
| Fuse | 2 A, 250 V AGC-2 per output |
| Environment | 0 to 60 C operating; 5-95% RH non-condensing |
| 02 |
FIELD CHECK
A four-part wiring verification |
| A
LABEL
Confirm 1771-OA Series and chassis slot.
|
B
ARM
Match the 1771-WA field wiring arm.
|
C
LOAD
Verify voltage, current, inrush and minimum load.
|
D
FUSES
Check eight AGC-2 fuses and common conductors.
|
| 03 |
OUTPUT MODULE CHOICE
Different voltage and isolation priorities |
| Model | Difference | When to use |
|---|---|---|
| 1771-OA FEATURED MODEL |
8-point 120 V AC | Exact installed match for a 92-138 V AC load design. |
| 1771-OAD | 12-120 V AC range | A wider low-voltage AC range is required. |
| 1771-OD | 6 isolated 120 V AC outputs | Channel isolation and higher point capacity are needed. |
| 1771-OAN | 32-point 120/240 V AC | Higher density is required after chassis and derating checks. |
![]() ![]() ![]() |
AMIKON LIMITEDProfessional service. More expertise and more choices. Faster global response. |
| Sales manager Miya zheng |
Email sales@amikon.cn | WhatsApp 86-18020776792 |
| Q1 | Can 1771-OA switch a 240 V AC load?
No. Its specified range is 92-138 V AC.
|
| Q2 | Can all eight points deliver 1.5 A together?
No. The total module current must not exceed 6 A.
|
| Q3 | What must match before replacement?
Series, chassis slot, keying, 1771-WA arm, voltage, current, inrush and fuse arrangement.
|
| Q4 | Why can a small load remain active when off?
Off-state leakage can reach 5 mA; verify load release or use an approved burden.
|
| Q5 | What should be tested after installation?
Command every point, verify indications and field action, then inspect fuses and heating.
|
| 80026-044-06 | SR2E201BD | 3500/33 149986-01 | AAI543-H03 S1 | 6ES5304-3UB11 |
| 2097-V34PR5-LM | IC630CCM300 | SD833 3BSC610066R1 | ADV551-P50 S2 | L5504AMP |
| 51403776-100 | LG-003842 | 6ES5430-4UA12 | MPL-B230P-EJ44AA | DDNP1501 |
| 146031-01 | EB501-50 S2 | 6DD1607-0EA1 | TK-HAO081 | 1C31203G01 |
| C100/0200/STD | 1785-BCM/C | H3DE-S1 | 3500/25 149369-01 | SDV144-S63 S4 |
| 6SE3122-4DG40 | C7076A1015 | IC630CHS308 | 07KT92 GJR5250500R0262 | 80190-100-01-R |
| 3RP2525-1BW30 | 3500/20 125744-02 | T7412B1008 | 6ES5482-4UA20 | 1783-US08T |
| GHQ6310062R0111 | 136188-02 | ATA4D-00 S2 | 6ES7195-7KF00-0XA0 | 51402497-200 |
| 7402-040-01 | SDCS-DSL-4 | A3C40173228 | TSXPSY2600 | 172103-01 |
| AAI143-H53 S1 | 6DD1683-0BC0 | 38500148-300 | LV429386 | SDCS-POW-1 |
After-delivery support01 Contact within 7 days with order details and photographs.
02 Retain the item, packing and accessories in original condition. 03 Approved return or replacement follows inspection; return freight is paid by the buyer. |
|



Inventory Products


More than 40.000.000 products available and worldwide support