ABB DRIVES / SAMI GS CONTROL PLATFORM
SNAT7640
3BSE003195R1
Control Interface Card for SAMI GS ACS 502–506 Frequency Converters
|
CONTROL INTERFACE
X50 + X51
Keypad / Serial Link
|
|
01 / CONTROL TERMINAL
X50
Analog, digital and relay I/O
|
02 / SERIAL INTERFACE
RS-485
X51 remote panel / serial link
|
03 / OPERATOR ACCESS
Keypad
Display and local operation
|
| Sales Manager: Miya Zheng | EMAIL SALES | WHATSAPP 86-18020776792 |
| Interface / Terminal | Signal / Range | Function |
| X50 / Analog reference | 0–10 V or 0–20 mA | External drive reference input |
| X50 / Digital inputs | DI1–DI6 | Start/stop, direction, speed selection and ramp selection |
| X50 / Analog outputs | 0–20 mA | Output frequency and motor current indication |
| X50 / Relay outputs | RO1–RO3 | Ready, run and fault status |
| X51 / Serial link | RS-485 | Remote panel and serial control connection |
|
01
Operator Input
Keypad and display
|
02
External Control
X50 signal terminals
|
03
Serial Link
X51 RS-485 interface
|
04
Drive Feedback
Ready / Run / Fault
|
|
Drive Family
Confirm the equipment is from the SAMI GS ACS 502–506 platform and verify the installed card designation and revision before ordering.
|
Terminal Assignment
Record existing X50 wiring, X51 connections, jumper positions and application macro settings before replacing the card.
|
|
Cable Routing
Use screened control cables and maintain separation from mains and motor cables to reduce interference coupling.
|
Electrical Safety
Isolate the drive from the mains and follow the prescribed DC-link discharge and verification procedure before accessing internal cards.
|
| Q1. Can SNAT7640 3BSE003195R1 be selected for every ACS 502–506 drive?
A1. Do not assume universal interchangeability across every cabinet configuration. Confirm the drive model, installed interface-card designation, card revision and existing connector arrangement before purchasing.
|
| Q2. What should be recorded before removing the original card?
A2. Photograph the X50 and X51 wiring, note the jumper positions, record the drive parameter set and identify the application macro. These details help prevent incorrect signal mapping after replacement.
|
| Q3. Can an external PLC provide the drive's start and speed reference signals?
A3. Yes. The X50 terminal block supports external control connections, including digital commands and an analog reference. The signal assignment must match the selected application macro and parameter settings.
|
| Q4. Does the X51 port support a multi-drive serial connection?
A4. The SAMI GS RS-485 bus supports communication between multiple units. Each drive needs a unique ID, and the last unit on an unterminated bus requires the specified termination setting. Cable length and screening affect reliable operation.
|
| Q5. What should be checked if the replacement card powers up but the drive does not respond to remote commands?
A5. Check the selected control place, parameter assignments, X50 digital-input logic, X51 wiring, serial ID and communication bit rate. Also verify the application macro and any required jumper configuration.
|
| 01 / Report
Contact us within 7 days of receipt if an issue arises.
|
02 / Return Condition
Keep the item in its original condition and provide the reason for return.
|
03 / Resolution
A refund or replacement is arranged after the returned item is received and assessed. Return shipping is the buyer's responsibility.
|
| 6ES7335-7HG02-0AB0 | AB7000-C | QD75P4N | X20BB22 |
| 6AV6642-0BD01-3AX0 | TDR2000/2R | AB7834-F | IC754VSF12CTD |
| NPSmini116 | 6SE7041-8EK85-1HA0 | GT2-P12F | 5AP920.1906-K07 |
| ALE111-S53 | XCL8010A XL800 | 5464-331rev | 12A0-0600-A6 |
| 6AV2124-0JC01-0AX0 | RB4U | AC1401 | P73-07788 |
| AB7699-F | GC1000 | 6ES7157-0AD82-0XA0 | FQC-08929 |
| N-8540DS | A0352 | ICX35-HWC-E | AC1402 |
| 5PP320.0571-39 | LR-ZB250AN | MMDS-CLC | 350-5851-01 |
| OPTO22 SNAP-LCM4 | 6AV6644-0AA01-2AX0 | 24347 | FVT4014M |
| 825-PR12D | DSP-Ex | 6ES7 505-0KA00-0AB0 | HS-NCM-WSF-2 |
| 5501-381 | GT-A10 | LICO620 | 6AV6642-0BD01-3AX0 |
| KFDO-CS-EX2.51P | 6SL3055-0AA00-4CA5 | X20CP1483 | AAI143-H50 |
| R2670B | NPACON4S | TV-620HC | AB7834-F |