ABB SSKT160-08 Specification
1.General Specifications: |
• Product Type : |
Servo Drive |
• Series : |
SSKT160 |
• Model Number : |
RE400AEPJH1ABB-P |
2.Electrical Specifications: |
• Input Voltage : |
400V AC ±10% (three-phase). |
• Rated Current: |
10-40A |
• Input Frequency : |
50/60 Hz. |
If you have something you want to know more,
you can contact us Miya!
Email : sales@amikon.cn
Skype :miyazheng520
Phone/WhatsApp : 86-18020776792
Overview
Wind Turbine 30Nm & 45Nm Pitch Axis Motor Speed Limit Retrofit Kit |
Product Status Active |
Structure Series Connection - All SCRs |
Number of SCRs, Diodes 2 SCRs |
Voltage - Off State 800 V |
Current - On State (It (AV)) (Max) 160 A |
Voltage - Gate Trigger (Vgt) (Max) 3 V |
Current - Gate Trigger (Igt) (Max) 150 mA |
Current - Non Rep. Surge 50, 60Hz (Itsm) 5000A @ 50Hz |
Current - Hold (Ih) (Max) 400 mA |
Operating Temperature -40°C ~ 125°C (TJ) |
Environmental conditions
Operating Temperature |
Vibration and Shock |
Range: |
5% to 95% |
Enclosure: |
IP20 Rating |
Purpose: |
-20°C and 70°C (-4°F to 158°F) |
Environment: |
Avoid locations with extreme temperatures, high humidity, or exposure to chemicals and vapors. |
Altitude: |
Generally up to 2,000 meters (6,561 feet) above sea level. |
Compliance: |
Must meet EMC standards to prevent electromagnetic interference with other equipmen. |
Enclosure Rating: |
Usually IP20. |
Ventilation: |
Ensure adequate ventilation around the drive to dissipate heat. |
ABB SSKT160-08 Technical Questions and Issues
1.Q: What should I do if the ABB SSKT160-08 servo drive does not power up? |
A: ♦Check Power Supply: Ensure that the drive is receiving the correct input voltage and that the power supply connections are secure.
♦Verify Wiring: Confirm that all wiring is properly connected and that there are no loose or damaged wires.
|
2.Q: How do I address fault codes that are displayed on the ABB SSKT160-08? |
A: ♦Identify Fault Code: Refer to the drive’s user manual or fault code guide to identify the meaning of the displayed fault code.
♦Check for Common Issues: Common faults might include overcurrent, overheating, or communication errors.
|
3.Q:What could cause erratic motor behavior, and how can it be resolved? |
A: ♦Check Parameters: Verify that motor parameters and control settings are correctly configured in the drive’s software.
♦Inspect Feedback Devices: Ensure that feedback devices such as encoders are properly connected and functioning.
|
4.Q: How can I troubleshoot communication issues between the ABB SSKT160-08 and other devices? |
A: ♦Check Communication Cables: Ensure that communication cables are securely connected and not damaged.
♦Verify Settings: Confirm that communication settings such as baud rate and protocol match those of the connected devices.
|
5.Q: What should be done if the ABB SSKT160-08 is overheating?
|
A: ♦Check Ambient Temperature: Ensure that the drive is operating with
♦Improve Ventilation: Ensure that there is adequate ventilation around the drive and that cooling fans or airflows are not obstructed.
|
More Recommend Items
ABB |
NTAI05 |
Bailey Analog Input Termination Unit |
ABB |
PM645B 3BSE010535R1 |
Processor Module |
ABB |
INIIT13 |
Infi-Net to Infi-Net Transfer Module |
ABB |
3HEA800906-001 |
Drive Control Board |
ABB |
SMIO-01C 68631343 |
Control Board |
ABB |
DSQC328A 3HAC17970-1 |
Digital I/O Unit |
ABB |
TPS02 |
Bailey Infi 90 Turbine Protection Slave Module |
ABB |
FS450R17KE3/AGDR-71C |
IGBT Module and Drive |
ABB |
CI531 3BSE003825R1 |
Interface Submodule |
ABB |
C100/0200/STD |
Commander 100 Process Controller |
ABB |
SPNPM22 |
Network Process Module |
We have more products and look forward to our cooperation!